Search results

  1. 2

    Recommend spotlight for exterior sofit.

    I wouldn't have rood for flood lights
  2. 2

    Recommend spotlight for exterior sofit.

    Just have nice lighting plus shine down on the stonework.
  3. 2

    Recommend spotlight for exterior sofit.

    I have a soffit overhang off 245mm from rendered wall to the start of fascia. Im putting new stone on the face of the house which is 165mm of the wall which will leave me 80mm for new spot lights. Maybe even 70mm or less so I the spots aren't tight against the stone and underside of the fascia...
  4. 2

    Needing guidance/tips on raising shed

    I already knew this, i will be getting it sprayed with spray on insulation.
  5. 2

    Needing guidance/tips on raising shed

    I bought a shed 2 months ago for storage for tools and weights etc.. was supposed to install it on a base when first arrived but with being so busy, I couldn't get around to it. Now thou, I have built up just over 300mm with blocks on its flat around the perimeter of the base and will be...
  6. 2

    Is this wrong isolater

    I always thought one wasn't allowed any switches in a bathroom/ensuite. Just pull cords. It's a 65mm insulated plasterboard on the ceiling.
  7. 2

    Multipoint door locking is on its last legs

    After searching more , was advised to try Wd40 and it has sorted it. Thumbs up
  8. 2

    Is this wrong isolater

    It's in the futherest part away from the shower. See rough sketch. 2m SQ ensuite. Isolating with fan is where X is
  9. 2

    Is this wrong isolater

    Are these allowed in bathrooms? I would prefer this than a pull cord
  10. 2

    Multipoint door locking is on its last legs

    Finding it extremely difficult to lock this door . I have two in the house and the one that I'm finding it difficult to lock, this round part at the top of the locking mechanism isn't going to the top of where it should. I's there an easy fix or is it a whole new mechanism and if so, what is...
  11. 2

    Is this wrong isolater

    I was thinking it wasn't right. Which one should I ask for
  12. 2

    Is this wrong isolater

    See diagram for isolating a new extractor fan in ensuite and new isolating switch. Everything is wired to diagram and working order the spots. The extractor was to be installed today but looking at the isolating pull cord, there's only 3 terminals yet there is 4 wires in the 1.5 cable. Is...
  13. 2

    Closed back toilet won't go back. Pics

    On a normal toilet maybe but a closed back to toilet, I'm not sure although I'll get both tomorrow and will see. Thank you for your replies terry. Much appreciated.
  14. 2

    Closed back toilet won't go back. Pics

    I just measured the one I have there. It's the first one you said . The wc-con8e. So, I think a normal one and extension piece will have to try that instead..
  15. 2

    Closed back toilet won't go back. Pics

    I was thinking maybe I could use a straight connector into the existing although I'd prefer if ya could get it, the first one you describe if the horizontal part isn't out to much.
  16. 2

    Closed back toilet won't go back. Pics

    I don't think if I take the tile out this would sort it. I'd have to go into the wall with a kangoo and this is alot of work, messy work too.
  17. 2

    Closed back toilet won't go back. Pics

    Excuse the mess. Few wipes and it'll be fine. The old pan connector is 160mm of the wall. See pic. From the toilet outlet, till the very back of the closed back toilet is 190mm. Is there any extension piece I can get to push that'll be 30,mm. I know this is extension straights but at...
  18. 2

    Closed back toilet won't go back. Pics

    The soil pipe is flush with the tiled wall. I hear what your saying. What is the alternative? Before I had a ridgid pan connector inside a cut soul pipe into the soil pipe connector. The only thing I can think off is to put the rigid pan connector back and try to line it up, push back and...
  19. 2

    Closed back toilet won't go back. Pics

    It's not the fixings. The top of the outlet is 230mm but when the flexi is a full 90, it's 250/260mm because of the old outlet in the floor. The only thing I can think off is a shorter flexi or cut this one but will I still get the bend I need for it. The last toilet had a ridgid pan...
Back
Top