    Dead boiler Vailant Ecotec Pro 28

    With the boiler off remove the large slot head screw from the front of the pump, insert a screwdriver into the pump and see if it turns freely, it may be seized. You will get some water dribbling out so have a towel ready.
  2. Jajodu

    Vaillant 835 e combi boiler.. Banging noise & HW issue

    What's the boiler doing while hot water is running? Is the flame symbol going out? Sounds like a circulation issue, blocked secondary heat exchanger perhaps.
  3. Jajodu

    Worcester Bosch 2000 Vs Baxi 600. Heating engineers Youtube comments

    I've always thought wb boilers to be like audi,, overpriced and unreliable.
  4. Jajodu

    Boiler Pressure Dropped from 1.5 to 0.2 in a Month

    Depends on how competent you are at this sort of thing. Looks straightforward, mains water off, boiler off and isolated, drain the boiler, remove and replace. Plenty of you tube videos on replacing one of these.
  5. Jajodu

    Boiler Pressure Dropped from 1.5 to 0.2 in a Month

    Depends on how confident you are in your abilities, it's usually best to replace it it it's leaking. Not a difficult job.
  6. Jajodu

    Shower pump recommendations

    I use the Stuart Turner for the shower but to increase hot water flow throughout the house I installed a flow flex sp2b in the 22mm hot water pipe from the hot water cylinder, works a treat.
  7. Jajodu

    Boiler Pressure Dropped from 1.5 to 0.2 in a Month

    You can tie a plastic bag over the outlet and see if it fills up. Another thing that can cause pressure variations is the expansion vessel needing recharging with air. There's a how to section on the method in the FAQs
  8. Jajodu

    Boiler Pressure Dropped from 1.5 to 0.2 in a Month

    Check the pressure relief valve outlet to see if it's wet.
  9. Jajodu

    Removing a sink plug/no nuts

    Why are you removing the waste?
  10. Jajodu

    Removing a sink plug/no nuts

    In your second picture you need to unscrew the metal connection from the waste, usually a pair of grips will suffice, try not to bugger up the threads, if there's no room then Disconnect the taps and plastic waste and take the sink off the wall.
  11. Jajodu

    Hot water system stopped working.

    Glad you're sorted, and in time for Christmas.
  12. Jajodu

    Hot water system stopped working.

    That should work.
  13. Jajodu

    Hot water system stopped working.

    Sorry, misread your original post.
  14. Jajodu

    Hot water system stopped working.

    I can't believe all three zone valves have failed. Time to get the multimeter out and measure whatsw happening.
  15. Jajodu

    Vaillant ecotec plus 837 pump wake mode

    You didn't say that in the original post. S07 means pump overrun anf the time it runs can be set in the boiler control panel.
  16. Jajodu

    Vaillant ecotec plus 837 pump wake mode

    Go online and download the installation and user manual
  17. Jajodu

    Vaillant ecotec plus 837 pump wake mode

    It's in the manual. One of the D settings.
  18. Jajodu

    Aquasystem ARB24 - Gledhill 250ltr - Pressure dropping

    In the FAQ section it tells you how to top up the expansion vessel. Do that first.
  19. Jajodu

    Vaillant ecotec plus 837 pump wake mode

    What time is set on the boiler for pump overrun?
  20. Jajodu

    Shower pump

    Yes it's good.