  1. C

    pilot light is not alight and thermocouple is changed

    definate overheat stat faulty,replace it there cheap as chips :)
  2. C

    Ideal Evo He fault code sos

    cant remember wot h3 is,ill try and look,i know h1 and h2 are flow/return thermistor fault codes :)
  3. C

    Baxi 105HE, Repaired it, but no hot water unless two taps on

    sounds to me as if the diverter is passing,with heating off turn hot tap on and check to see if heating flow pipe gets hot,if it does it needs a new diverter valve
  4. C

    baxi 80e lack of hw and leak from the gub screw on diverter

    ure looking at £100 for the full valve and 80 for just diverter,for the sake of 20 quid just order complete unit and be done with it :) the end :lol:
  5. C

    baxi 80e lack of hw and leak from the gub screw on diverter

    u need a new diverter valve.part number- complete diverter inc hw flow valve-248061 if the hw flow valve is ok then u just need the diverter body part number-248062 p.s the hw flow valve is the brass unit that the pin pushes out from
  6. C

    baxi 80e lack of hw and leak from the gub screw on diverter

    to cut a long story short ure diverter is knackered hence luke warm hw,its passing to rads instead of fully heating the plate h-exchanger,do u know gc number of appliance,it should be on the fold down lid somewhere and i maybe able 2 help u some more,when u changed the hw diaphragm how many...
  7. C

    baxi 80e lack of hw and leak from the gub screw on diverter

    is the boiler a combi instant 80e or just a combi 80e??they have different diverter valves.
  8. C

    baxi 80e lack of hw and leak from the gub screw on diverter

    with regards to luke warm hw......turn hot tap on and does the heating flow pipe get hot??if so it will need a new diverter
  9. C

    baxi 80e lack of hw and leak from the gub screw on diverter

    do u mean the leaking from the nut where the pin comes out???
  10. C

    baxi 80e lack of hw and leak from the gub screw on diverter

    kantago-where is this grubscrew located that u mean?? clf- leaking from wot "o"ring?? the grub screw i mean is located below dhw flow valve that keeps the flow valve attached to main diverter valve..... :?
  11. C

    baxi 80e lack of hw and leak from the gub screw on diverter

    sounds as if its leaking from the main diverter body,its a new diverter valve im afraid :( straightforward to change tho if u have good access on the left hand side :)
  12. C

    baxi barcelona

    replace control p.c.b if it hasnt been changed,baxi had an issue with them shortin on the board.p.s the boiler is a bag of nails-the h-exchanger will leak next,then the flow switch etc etc :)
  13. C

    Strike one for the little guys

    brown bose aye??wtf??.as ive said b4 cant understand why installers slag off bg??they have 9000 engineers and plumbers narrow them down to all parts chuckers and crap engineers??complete bulllshit to be honest.they have more fault finding info available to them than any white van man so u are...
  14. C

    Baxi Solo 40/4 Not ingniting.

    rgi territory im afraid :)
  15. C

    Strike one for the little guys

    can somebody pls tell why bg engineers are referred to as "parts changers"????
  16. C

    Strike one for the little guys

    well said ollski,too many white van men on here stuck up their own arses
  17. C

    Air lock in Gravity HW - cant shift it!

    Waite for the loud rumble thru the pipes then turn the stat off!yes if its shooting thru vent pipe then its boiling over.do it a couple of times then it will shift eventually.
  18. C

    Air lock in Gravity HW - cant shift it!

    U need 2 chk 2 see if u have a blocked cold feed,boil it up a couple more times,if that fails ure cold feed is blocked
  19. C

    Keston Celcius 25

    Yeah get on contract with british gas,its a safe bet if u cant afford 2 replace it.when these get 2 a certain age they breakdown consistently all the time.parts are very expensive for them
  20. C

    Keston Celcius 25

    either get on a heating contract or have the boiler replaced,these are a bag of nails and its gonna cost u a fortune in parts cost over the years if u havent got a contract