Search results

  1. H

    Smart Door Lock Coice Advice

    I'd like to know what your insurance company says about that.
  2. H

    Texecom config query - entry/exit and guard access

    Front door should be entry/exit (final door) with Hall pir guard access. Don't know why he's used entry/exit 2. If the door was not opened and then closed then alarm would not set when using entry/exit, as the correct setting function has not been carried out correctly.
  3. H

    Outdoor contact sensor for Texecom Premier Elite 64 system

    Impact SC W has same option to wire additional contact. Install heavy duty sealed contact or RS contact to gate and wire back to wireless device in IP rated plastic box.
  4. H

    SDS bit snapped in brickwork - what to do?

    Drill new pilot hole directly next to the 6mm hole.This may dislodge the broken bit,then redrill with larger size bit .
  5. H

    How do we figure out why our Texecom Premier Elite wireless keypad is tampering?

    Check keypad is correctly fitted to wall.Check tamper microswitch has not been damaged on keypad pcb when unit was installed. Also suggest change batteries for new one's.
  6. H

    Texecom Elite 64 timed disarm

    Control panel needs to be v4 or above..If not then firmware would need to be flashed. Press menu 4 on keypad will tell you panel version. You will need smartcom and set up Texecom cloud account Subscription is currently free,but may charge in future.
  7. H

    pyronix sim card

    Best to pay for GPRS pyronix app fee. Pay as you go sims can has setup issues. Have you paid for you existing service? Failed to connect suggests that not live connection or not setup correctly. Uninstall app and then reinstall app and setup with app password and system ID.This information is...
  8. H

    Remove Novar ED&S wireless alarm system

    Total power down system and Disconnect bell box if rings once powered down. Then if new system.
  9. H

    Hikvision DVD DS HUHI 7408 K1 - cameras looping

    Possible fault power supply to DVR.
  10. H

    ADT nightmare

    If you no longer pay a maintenance fee then ADT shut down the monitoring connection. This will cause a arc fail.
  11. H

    ADT nightmare

    Do you have a live maintenance contract for your system with ADT
  12. H

    Extra thick electric front plates?

    Google socket spacers,lot available to space off that socket.
  13. H

    Texecom - adding new wireless keypad.

    You would be better off with a wired keypad straight swap to replace damaged one. You will need to learn the new wireless keypad on to your system .
  14. H

    Texecom - adding new wireless keypad.

    What Texecom control panel do you have? Does to have ricochet expander/ wireless panel. Why have you purchased a wireless keypad to replace a wired keypad.
  15. H

    Pyronix smoke alarms

    Pyronix smoke-we are wireless devices. Your system will require a wireless expander for these to work.You can purchase 12volt smoke detectors which can be wired to your alarm system.
  16. H

    Engineers keypad Lead

    From outside edge Blue = T Yellow = R Black = - Space /not used terminal Red = +
  17. H

    Texecom Premier Elite User menu

    Your panel shows bell tamper and aux tamper linked out.The control panel tamper requires a link putting on the jumper next to the spring at top of pcb(tamper disabled). Make all zones as spare/not used.You should now have no faults on your system. Now set up your smartcom. There are plenty of...
  18. H

    Texecom Premier Elite User menu

    Best thing to do is start from scratch. Link out bell tamper return on panel,put Jumper on control panel tamper.leave all zones as not used. Post photo of panel wiring. Have you registered with Texecom .
  19. H

    F133 alarm

    Faulty battery?
  20. H

    Texecom Premier Elite 24 not alarming/triggering when full set

    Have you set part set function from zone attributes for each device and not used Area A or Area B as part set-up
Back