Search results

  1. Exedon

    What have I done here ? I only wanted to change a faulty zone valve

    As above incorrectly wired. I take it your 3 port is a Y plan mid position valve? Maybe clear picture of what's happening in junction box? To be blunt I would just fit a 2 port wire it correctly and move on.
  2. Exedon

    New toilet and flange problem.

    Some clear pictures would be useful.
  3. Exedon

    Post the best photo you took today

    It's a Anthony Gormley instalation on Crosby beach 100 full size cast iron men looking out to sea. Today the tide was in. It's really called another place!
  4. Exedon

    Post the best photo you took today

    Another Place
  5. Exedon

    Lead work on slate roof around new wood stove flue, is it right?

    Should have been correctly slated in . Depending on how much lead goes under slates at back of flue may not even be water tight or dependent on silicone.
  6. Exedon

    Oil burner position for single floor rear extension

    When we are looking at oil boiler changes especially if in new position we fit look if there was a place to fit a external boiler They are just as efficient take .up no room inside no smell of kero in building normal cost neutral compared with internal boiler. If fitting a internal boiler...
  7. Exedon

    Post the best photo you took today

    Correct We worked here when it was brought back to life. Beautiful building.
  8. Exedon

    Post the best photo you took today

    View from our hotel room
  9. Exedon

    Fitting a new water tank ball cock valve, connector terminology

    If that is all one casting I've never seen one like that but the market is full of foreign tat!. Try screwfix they certainly stock correct one. You could just change the whole thing but that may open up another world of pain.
  10. Exedon

    Fitting a new water tank ball cock valve, connector terminology

    That looks like a standard 1/2 in part 2 ball valve that's been taken apart at Union nut. Replacements easily available just search for Part 2 ball valve good idea to change float at same time .
  11. Exedon

    How to cap off?

    That's a 1/2 in threaded back plate so any 1/2 in plug will do, I'd use one intended for radiators as they include a O ring.
  12. Exedon

    Broke a gas pipe

    On a large new build site a ground worker asked if I had any duct tape. They had chopped strait through a 25mm gas service and proposed taping it back together! By good luck I had 25mm cap in van I then phoned Northern gas network.
  13. Exedon

    Identifying shower valve

    Mail a pic to showerdoc.com Simple as that.
  14. Exedon

    What if a drilled hole is too big?

    If the plaster is taking 70% of the load you need deeper holes and longer screws Unless wall is exceptional hard I would always use a 5mm drill bit for red plugs 6 mm for brown. Anything vaguely heavy (radiator or similar) we use concrete screws.
  15. Exedon

    Ideal Boiler default DHW Temp

    The idea of running at 80c is to keep the dhw reheat time as short as possible. Then the boiler can revert to running at a lower (condensing) temperature. That control system do you have? We use ideal vogue boilers on x plan with weather compensation. Mated to a cylinder with high performance...
  16. Exedon

    SALUS RT510 > HIve

    The rt 510 is a battery powered programmable room stat Live in should be on 1 (common) switched live out on 3. Why you also have a separate thermostat really needs checking out!.
  17. Exedon

    GPlan Table

    Decent advice As a side line we buy/sell 20th stuff . There is a demand for mid century furniture but prices have dropped a bit. G Plan extendable table with chairs in good order £300/£400 Table on its own needing restoration I would just ebay it.
  18. Exedon

    Is this wired right

    Better be clear re motorised valves. The standard control system for heat only/system oil boilers is S plan . The number of oil boilers we have installed over last few years is well into 4 figures. The only time I've known a oil boiler overheat stat work is Failed boiler stat System...
  19. Exedon

    Is this wired right

    As above but I very much doubt you oil boiler requires a pump overrun . The water capacity of oil boilers is huge compared with gas boilers.
  20. Exedon

    Diamond Core drill

    Marcrist 850 core bits are intended to do exactly that percussion drill required not sds! Very quick cutting & slow diamond wear.
Back