  1. aptsys

    No Main Earth Connection

    Correct, it is. PME is not synonymous with TN-C-S, TN-S, TT or any other arrangement.
  2. aptsys

    EMF Final Distribution substation

    I wouldn't worry then. Enjoy your high PSCC!
  3. aptsys

    EMF Final Distribution substation

    EMF is a pretty useless term in this context and the "meters" are just as nonsense, especially since they are typically wideband so the reading on the display bears no relevance to any specific frequency of interest. If you're concerned about magnetic fields, there are regular items you will be...
  4. aptsys

    Three lamp ceiling light - changing back to single

    Indeed you can see it hiding there.
  5. aptsys

    EMF Final Distribution substation

    What are you looking for?
  6. aptsys

    Fluke T130 on loose wires

    Fluke AC175's screw straight on to the little thread on the probes
  7. aptsys

    Fluke T130 on loose wires

    They're from this kit: https://uk.rs-online.com/web/p/multimeter-leads/3245975/ But there's many different types available, Pomona and Keysight leads also have these. Fluke AC175's fit.
  8. aptsys

    Fluke T130 on loose wires

    I use these:
  9. aptsys

    Surely this is wrong.......

    Sorry, just me and semantics. You can always "do" something, as illustrated by the photo. Whether you should or not is a different matter ;)
  10. aptsys

    Gas hob ignition & electric oven on the same switch

    A 16A plug must be protected by a 16A MCB, so no that's not a possibility in the way that you describe it.
  11. aptsys

    Gas vs Electric Oven - Gas vs Electric hob

    Induction hobs are excellent providing you buy the right one. They're far more controllable and put significantly more energy into the pan, but some find it hard to adapt between judging the gas flame vs an arbitrary number between 0 and 15 for example.
  12. aptsys

    Boiler Replacement?

    I wouldn't recommend it. As mentioned, either stored water or possibly one electric shower will be better. Don't get the builder to quote for a boiler - get someone who knows what they're doing.
  13. aptsys

    Finding the right PIR light

    My usual recommendation would be to separate the PIR and the lamp. Robus do a decent PIR which can be used with an override, and it can be paired with any lantern/fitting.
  14. aptsys

    Gas hob ignition & electric oven on the same switch

    Exactly. The 2.99 kW will be at 240V, as you say - worst case power consumption
  15. aptsys

    Surely this is wrong.......

    They can, but they shouldn't (n) Document with photos, and call your landlord to sort. A Class I fitting with no earth is not acceptable.
  16. aptsys

    More 'RCD Type' uncertainty/confusion

    Under what scenario would you see a DC bias on the AC supply without the item in question going bang? The low source impedance of most domestic AC supplies suggests to me that this would not be possible.
  17. aptsys

    Identify this connector

    JST ZH or Molex Picoblade. Difficult to tell with the blurry pics.
  18. aptsys

    Inverter earth

    It depends on the topology of the inverter and the isolation between the input and output.
  19. aptsys

    Failed EICR

    "33 Consumer Unit not in order - C2" wtf? I also see no issue with "Oversized breakers" Please do instruct your own electrician to perform an EICR.