    garage foundation.

    I was thinking maybe this is what it was. This is how raft foundations are poured.
  2. 2

    garage foundation.

    One says better and the other says not better :( Im scratching my head now as to what one to choose! When you say the slab cracking, is this the actual strip foundation or the actual 150mm floor slab once that is poured. I googled slab thickening toe, i dont know what this is or ever heard...
  3. 2

    garage foundation.

    I agree bt the regs here for min strip is 3 times the width of the walls. 300mm thickness aswell. It is excessive but the more concrete, the better the foundation!
  4. 2

    garage foundation.

    Its the regs here where i am unfortunately! The ground conditions are good. 900wide x300 thick in a 600mm trench min regs. If its a single skinned wall, it can be 300 wide. Here the regs are whatever thickness your block walls are, you multiply by 3. The cavity plus 2 100mm block is 300mm...
  5. 2

    garage foundation.

    If youve no foundation under one of your walls in the converted garage, whats holding the walls up?
  6. 2

    garage foundation.

    This also crossed my mind but then id have to build up again with maybe block on flat for a strong base for the cars to drive over. At most, i think its 2.5 cubic meters of concrete and whatever block is needed.
  7. 2

    garage foundation.

    I thought id start its own thread on this query i have concerning strip foundations of a garage. If the garage foundation will be a strip foundation 900 wide x 300 thick with 10mm wire mesh or rebar for a double skinned block walls with 100mm cavity, then later a 150mm slap poured with 10mm...
  8. 2

    Sewer pipe going through footings

    I will dig out and get measurements. What bout the footings under the roller door, should i install concrete footings or leave out.
  9. 2

    changing roof pitch

    The 3.1 m is from ceiling height to peak. I wasnt taking in below the ceiling. 6 m is on the plans.
  10. 2

    Sewer pipe going through footings

    One thing that i forgot to mention in the OP. When building a garage, and when digging out the footings, if i have a 4m wide opening for the roller door, would i need any footings under this gap under the roller door. Isnt it just where the walls are getting built above! I was of the thinking...
  11. 2

    Sewer pipe going through footings

    The trench will be 600 deep, 300mm thickness of concrete with 2 course of block above to dpc level. The strip foundation will be a ring right around teh building on the same level without any steps. When you steps, what do you mean? When you say form a hold, is this as in pic above o as i...
  12. 2

    changing roof pitch

    :ROFLMAO::ROFLMAO: Ive a bowl of dingle berry soup put away for a special occasion. Ill share it with you if youd like. But first, i need an answer haha
  13. 2

    Sewer pipe going through footings

    Its the orange 4 inch sewer pipe and nothing wrong with it. Your the second person who mentioned the lintel and ive seen it done in block,brick work and even have it in a diagram in a building regs book i have however it doesnt show the pipe going through the actual concrete footing. When you...
  14. 2

    Sewer pipe going through footings

    Is this what you are talking about. I found this on the internet! Would this not cause problems if the ground moves more on one side, it will cause cracks above in the block work.
  15. 2

    changing roof pitch

    My span would be 8.5m from outside wall to outside with a a double skin of 100mm block and 100mm cavity included in the 8.5m. The height would be 3.1m and works out at a 35 degree pitch. If i was to drop the peak half a meter, what would the pitch be?
  16. 2

    Sewer pipe going through footings

    So the concrete lintels go in the footings?
  17. 2

    Sewer pipe going through footings

    Can you clarify more. Will the pipe still be surrounded in concrete ? I have worked with pipes going through block footings but can only remember once working with pipes going through the actual concrete but that was working for a builder who wasnt the best for keeping to regs. If i do...
  18. 2

    Sewer pipe going through footings

    A garage will be getting built on my site just behind my house soon however ive just noticed that there is a 4inch sewer pipe coming from the house to the septic tank that will be going through the garage. After taking measurements, i have noticed that the pipe will be running through the new...