Search results

  1. F

    Lead Singles Cable

    All good ideas Ken. Thank you
  2. F

    Lead Singles Cable

    I can't see a PM for some reason? It is a charity and being done with various funding.
  3. F

    Lead Singles Cable

    I am going back there in a week or two to have a play and see what I can come up with..
  4. F

    Lead Singles Cable

    That's good to know. :)
  5. F

    Lead Singles Cable

    Interesting, I didn't know any would still make a lead sheathed cable. Smallest size there is 10mm csa..
  6. F

    Lead Singles Cable

    Are you saying that inside the lead sheath is a rubber insulator (not cloth as I previously thought)? Would a bare copper MICC be ok in a salt water environment? Obviously the ends would need terminating properly!
  7. F

    Lead Singles Cable

    Excuse my mistake - I was only going on what I thought I heard.
  8. F

    Lead Singles Cable

    More info can be found here if interested. http://www.ssfreshspring.co.uk/
  9. F

    Lead Singles Cable

    Do you have any recollection of this type of lead cable or the glands etc?
  10. F

    Lead Singles Cable

    No it’s in Devon
  11. F

    Lead Singles Cable

    In use at 24v if possible.
  12. F

    Lead Singles Cable

    I don’t know as I have only had a quick look so far. It’s nice isn’t it?! It’s in the last surviving steam ship in the world. Being refurbed.
  13. F

    Lead Singles Cable

    i have a job rewiring an old ship - it currently has lead sheathed cable with what looks like a single core with perhaps a cloth insulator? It dates back to the 1940’s. Originally it was all 110v dc. The lighting has now been converted to 24vdc and The customer would like to keep a lot of the...
  14. F

    Solar Charger

    I checked the voltage from the panel on an afternoon last week - it was sunny but around 5pm - I was getting 18v.
  15. F

    Solar Charger

    I have a 20W Solar panel system which charges a 7AH Lead Acid battery. This works fine when no load is attached to the battery. We are then connecting a electric fencer unit, which is 12V 200mA. This load is running 24hrs / day The solar panels are not able to keep the battery charged up, and is...
  16. F

    Circuits triped. now what

    Your picture shows the mcb in your garage consumer unit are both off. Reset the lighting one by pushing down then back up. Push the socket one up.
  17. F

    Consumer Unit Replacement

    :mrgreen: It was late and I didnt want to read through 8 pages there and then!!
  18. F

    Consumer Unit Replacement

    Gazer where are you? Perhaps someone here can help?
  19. F

    Megger 1721 2 wire test

    i have a new megger 1721 (always had fluke before). Today I did a 3 wire low current loop test and got 0.30. Then tried 2 wire low test and got a reading of about 2.30. Why’s it so different.? Thank you!
  20. F

    Cable size calcs for motor

    I need to put a supply in for a 22A FLC 3ph motor (fan unit). Cable length is about 100m. I am not sure on the motor connections as inside the terminal box there is just the 3 line conductors, and no options to fit star/delta links. What would be the maximum permissible volt drop on start up...