The creeping forward is actually a good thing, when you are on a incline you won't roll back.
When you come to a stop just put your foot on the brake and wait, if its going to be a longer wait for some reason then go into park & handbrake on.
Who.. is me.
I calculate I need this upgrade. Admittedly most of my electrics background is automotive and recently lithium LBs (where it works a bit differently, you only have a finite number of amps to use so you have to work out what your draw Ah is for how long it'll last) but I am...
Thank you @Taylortwocities , good to know.
I measured the outside of the cable using a Vernier guage so it is like you say, most likely already 25mm2 which is reassuring.
Hi,
Our bungalow has 60a, will need upgrading to 100 which UK Power networks will do FOC.
I have what I measure to be 10mm cable in and out of the meter into fuse board.
For anyone who may have experienced (or even had done) the upgrade my Q is, do they (UKP) upgrade to the meter only or also...
Thank you to all replies, Henley block ordered.
I was concerned about the seals but I think I can work around without disturbing.
Thank you again, I really do appreciate the help.
Pg
Hi,
I am working in a flat at the moment and there's a redundant circuit in there, the old Economy 10 (or 7) The storage heaters are long gone, sockets left in the place of the wall connection box.
It makes sense to enable these for daily use and the wires for each (red at top of pic) were...
Hi,
I wonder if anyone could help with the right product advice .
Our old lead flat gulley roof was leaking so had a fibreglass roof which was told would last. It's a bungalow so easy to access.
At the end of the gully it's not flowing away from the building, it slopes back so water sits and...
thank you to everyone for the replies. makes perfect sense that it would be a nuisance (if it was AFDD on the main 63) , I just hadn't thought it through that way so thank you again.
It's peace of mind, a step forward, call it what you will but I'd rather have extra protection than less. Yes expensive but I'd never forgive myself if something happened.
I've only recently become aware of them but they do seem to polarise opinion but makes no sense. What's negative about...
Hi,
Helpful members recently guided me to AFDD rcbo.
Arc Fault Detection Device.
Different AFDD on the market, 32a, 10a, 6a and others for the circuits, I'm slowly accumulating but my question is should the main 63A also be an AFDD ?
Thank you
I've now got three 32a to be fitted, buy a couple each month as quite pricey, but should the main breaker fuse also be swapped to afdd i.e should I be looking to buy replacement for that as well. ?
My consumer unit (plastic) will be upgraded so I'm going to get everything I need before getting...
This scenario terrifies me as it happens so often, plenty of threads on this forum.
The cause is normally the same
My question, what socket can catch this before melting takes place, more sensitive to the resistance because it's not unheard of for melting to happen but fuse not blow. I've had...
Thank you for all the replies. Up until quite recently I wasn't bothered about moss but what I find is it holds the water like a sponge and seems to have gone mad recently, has got out of hand.
This is the view from kitchen window of the front room roof.
Roof lot of moss.
Have sodium hyperchlorite ( dilute 1 to 3 or 4)
Is the right method to apply the sodium hyperchlorite (spray) watering can applied) then gently pressure spray off.
or..
I've seen some people just go straight into pressure washing with no pre treat.
A roofer suggested using...
Looking again the final decision is to pull it all down and start again. Low bricks are blowing, high placed bricks are blowing. We plan on staying for years so time to get some quotes to rebuild properly with bitumen back, damp course at the bottom and decent bricks. We will paint it afterwards...
Thanks everyone, helpful to know and understand the problem.
Bit of an update, There was a builder opposite who had a plasterer working with him. They came up with a solution to place a coping brick on the top with a slight overhang and also dig out behind and put in a sheet membrane barrier...
Our retaining wall looks dreadful. Bricks blown, we painted it but the bricks keep blowing.
What do we do.?
End result would be nice to have the engineering top and paint the sides but want to have a solution that will last and looks nice.
Holding back the earth as you can see.
Some blown...