Search results

  1. gasman26

    What do gas engineers install in their own homes?

    hmmmm.... I didnt know that was possible :D
  2. gasman26

    What do gas engineers install in their own homes?

    In my own house: Remeha Avanta 35c, Honeywell cm927 prog room stat, drayton trv 4`s, santon 250l unvented cylinder. In my rental properties: Baxi bermuda 552 back boiler Remeha Avanta 39c Glow-worm ultimate 50ff Glow-worm 24cxi Remeha Avanta 24s Ideal classic 60ff baxi 105e...
  3. gasman26

    What Size Radiator do I need.

    800w x 600h double panel/single convector
  4. Untitled

    Untitled

  5. gasman26

    Fixing Pipes To Foam Insulation

    oooooo.... is this one of them conundrums, give me the first clue pleeease...
  6. gasman26

    Remeha Avanta Plus 35c

    I dont blame them really Chris do you? The customer knows they have to get it serviced to validate the warranty, we state this on the quotation & usually do the annual service. All the manufacturers are the same, Broag aren`t really that fussed whether it has been registered, they know the...
  7. gasman26

    Remeha Avanta Plus 35c

    Why you shouting? I was simply pointing out it is possible to give the 35 the same DHW performance as a 39, perfectly safe to do so. I was shown by one of the senior engineers at head office (Wokingham) We have been agents for Broag for 6 yrs, Broag only have a handful of engineers I wasn`t...
  8. gasman26

    Remeha Avanta Plus 35c

    The slightly bigger burner & primary hx are to accomodate the increased output required for heating. The 35 & 39c have the same plate heat exchanger (S62776), you can increase the fan speed by 10% on the 35, gives you the same DHW performance as a 39. I dont want to post on here the full...
  9. gasman26

    are these valves closed?

    Def looks like a Ferroli (poor sod :D ) I should imagine the property is a repo, all drained and isolated.....
  10. gasman26

    Remeha Avanta Plus 35c

    Just buy a 35c and adapt the in built parameters to make it into a 39c.... 35 & 39 are the same boiler, just have different settings..... max fan speed being one of them :wink:
  11. gasman26

    Remeha Avanta 18V

    P3 needs to be set to 2 CH on and DHW off.... it should be factory set to 2
  12. gasman26

    Remeha Avanta 18V

    Corgi are no longer running the register for gas engineers, you should be looking for a GasSafe registered engineer Try these http://www.gassaferegister.co.uk/ As somebody has stated before this is a heat only boiler and has no pressure/flow sensors fitted. Bleeding the radiators is not...
  13. job

    job

  14. gasman26

    Top fill boilers

    i would fit a Remeha Avanta 28c or 35c, with optional stand off frame (30mm deep) & pre formed pipework kit which brings all the connections to the top of the boiler. I replaced a glow-worm compact couple of months ago, all the pipework connections are in the same position, easy job :lol...
  15. gasman26

    We operate around the lincs/cambs areas, our number is in my profile if you require a quotation.

    We operate around the lincs/cambs areas, our number is in my profile if you require a quotation.
  16. gasman26

    baxi back boiler

    Seems like you been enjoying yourself too much tonight too, your beer goggles read Several as Seven me old fruit... We have decommissioned several back boilers over the years and left the fire front in use, on advice from the manufacturers...
  17. gasman26

    NAIL through pipe !!! Classic idiot ( yes me ) T piece ?

    Sell the house.... Dont leave a forwarding address.... :twisted:
  18. gasman26

    replacement combi boiler

    Would go as far to say, better than vaillant, (and not just based on after sales service) :D
  19. gasman26

    BAXI COMBI 105e..... HOT WATER BUT NOT TO RADS

    Unblocked one on wednesday :wink:
Back
Top