Search results

  1. C

    Weeping tee to expansion tank - help please

    If your capable it’s a simple repair, drop the system pressure , undo put some sealer on and refit and refill
  2. C

    Shower Tray Riser Kit?

    New kit
  3. C

    380mm Wide Chipboard Flooring (for loft)

    Check “loft boards “ think they are narrow to get through loft openings ,try B and Q
  4. C

    Underfloor heating issue - Hot Water Light off, system not heating

    You can buy just the head, it’s normally a stiff spindle it operates that burns them out.
  5. C

    Underfloor heating issue - Hot Water Light off, system not heating

    Is the underfloor pump running ,is the underfloor zone valve opening
  6. C

    Skirting for curved bay

    My bay windows ( same era) the skirting in the bays are plaster , rest of room wood .
  7. C

    Weeping Radiator Tails

    Reseal, check it’s not leaking from above and running down
  8. C

    Please help! 1 cold radiator

    It may be partially open JohnD but not enough for a decent flow
  9. C

    Boiler Thermostat

    You could try bringing the receiver out ,to see if it’s a control problem..Power off first !
  10. C

    Please help! 1 cold radiator

    The thermostat valve body pin maybe free but the valve can stick,can you remove to check?
  11. C

    Please help! 1 cold radiator

    Have you checked the pin under the thermostat head is free ?
  12. C

    Dumb waiter style lift for disabled dog

    Would think to get enough width a joist would need altering ,bit bigger job than estimate. Can you rig something over the banister?
  13. C

    What size tubular heater to keep black mould at bay?

    Add some ventilation to the wardrobe as well if possible
  14. C

    Vaillant Turbotec Plus heating not working

    Power off remove 3 and4 and make safe ,link 3/4 on terminal s ,power on and see if heating works
  15. C

    Chase these pipes into wall and behind skirting

    Chase wall out just above the elbows and use a straight coupling,alter pipes to suit
  16. C

    10yr old Worcester Bosch Greenstar CDi only used for 2 years and stored since, worth installing?

    Can’t see it myself ,won’t know it it’s any good till it’s been fitted then if faulty cost of repair,
  17. C

    Replacing Drayton digital RF1

    Yes they both work
  18. C

    Replacing Drayton digital RF1

    Screwfix do a new room stat/ receiver as a straight swap £109 , in my experience it’s normally the receiver that fails ,very easy to fit yourself , just turn power off before starting.
Back
Top