  1. G

    Pipe bung 8mm

    A bit of bread is what the old guys used to use
  2. G

    Magnetic Filter Install

    the prv is the first thing to check before suspecting anything else To check if it is going out condense pressure upto 2 turn the two valves off under the boiler leave for a day if possible if pressure drops you know its on the boiler and likely to be the heat exchanger leaking into condense...
  3. G

    Magnetic Filter Install

    does the pressure on gauge rise when boiler is on and do you mean it drips out the little copper pipe that pokes through the wall
  4. G

    Magnetic Filter Install

    What other problems other than The flexible pipe to expansion vessel, on these has a small bore and a tight bend and dont need a lot of muck to block up .
  5. G

    Room thermostat not connecting to CH boiler

    next time you are there disconnect the live red wire in the stat safely so no one can touch it ..... If the boiler still stays on then its an internal fault on the boiler
  6. G

    Room thermostat not connecting to CH boiler

    with clock off and stat turned down can you put a pic up of front of boiler and what its doing. And as per country fan do you just have one stat as in you dont have separate controls upstairs and down stairs or underfloor heating ?
  7. G

    Room thermostat not connecting to CH boiler

    i missed the pic of the combi
  8. G

    Room thermostat not connecting to CH boiler

    it will be a faulty motorised valve then , not the stat
  9. G

    Room thermostat not connecting to CH boiler

    does the heating go off when the clock/programmer is set to off
  10. G

    CH Pump Problem

    did you look at the level before draining ? 5 minutes would drop the tank by more than a third
  11. G

    CH Pump Problem

    do it for more than a few seconds but a minute /90 seconds should do it
  12. G

    CH Pump Problem

    drain some water off and see if you can hear the header tank filling up if you cant you have a blocked cold feed
  13. G

    Main soil drain

    if it goes to a shared drain then it could very well be covered for free from your water supplier the rules changed a number of years ago Worth giving them a call
  14. G

    CH Pump Problem

    leave big screw off pump and turn everything on check if the internal screw is spinning freely its very rare the impellor actually comes off. pump making an noise / boiler only staying on for 30 seconds no water out of highest point Do you have a header tank in the loft supplying the boiler ...
  15. G

    What is this bit that's leaking? (Baxi)

    It will be on the flow pipe from the boiler
  16. G

    Old tail pipe stuck in central heater

    hacksaw blade into the hole and do a few cuts taking care not to damage thread in the rad and it will come out using hamer and a flat blade
  17. G

    What is this bit that's leaking? (Baxi)

    No need to put a safety valve back in a black iron plug will do .
  18. G

    What is this bit that's leaking? (Baxi)

    its an old fashioned safety valve from the 60/70`s under all that crude are relief holes it can be taken out and plugged off as they are not required anymore . we used to just cover stuff up and just snatch them . Although the tee is 22mm (or 3/4) the valves came in either 1/2 inch or 3/4 ...
  19. G

    Heated towel rail not working how do I find the valve?

    yep does it look like it has an allen key socket inside it if not do what densso says