  1. G

    Pipe identification

    is there metal pipe under the plastic ?
  2. G

    Gas fire ignition

    yes they will and depending on what contract the appliance is on and where the part is sourced from they used to reimburse the cost
  3. G

    Help wanted on a leaking draincock (?)

    have you tried tightening it . Other than that take apart and change the washer...
  4. G

    Baxi 105e inlet manifold

    when it does stick up and making microswitch . there is a hole under the diaphragm that gets slightly blocked and needs poked out
  5. G

    Baxi 105e inlet manifold

    its came off the microswitch so should be ok if it was fully up still making the microswitch after demand it would stop the boiler from firing next time there is a demand
  6. G

    Baxi 105e inlet manifold

    yes but have look on ebay you will get legit old style pumps heads quite cheap
  7. G

    Gas wall heater lighting

    im telling you that blowing it with a straw to get it to light is impossible unless you have compromised a seal which you shouldnt be doing and its an absolute basic appliance to repair that no one should have any problem diagnosing what is wrong with it . It only has a handful of working parts...
  8. G

    Pressure Relief Valve Pipe Discharging internally

    Yep that is perfectly ok to do ignore notch
  9. G

    Gas wall heater lighting

    baxi / valor wall heaters are as basic as they come and probably one of the most reliable robust appliances out there that will last decades .In the past i have fitted several hundred of them they take minutes to diagnose and repair on the very very rare occasion they play up
  10. G

    35kW combi, 15mm CH pipes, 22kW rads - problem?

    22MM is far better but If it worked beforehand then you have added quite a restriction by using 15mm hep instead of 15mm copper
  11. G

    Gas wall heater lighting

    To be able to blow on the pilot light you must be breaking a seal
  12. G

    Gas wall heater lighting

    is it a baxi wall heater ?
  13. G

    Baxi 105e inlet manifold

    that is the venturi completely different part from what is being spoke about in video. you want the filter in the last valve on right hand side (22mm pipe )
  14. G

    Ideal Standard Cistern Replacement parts

    If you toilet is still running after flushing then get hold of middle bit and give it a quarter turn there is a silicone /rubber washer on the bottom that wear . Just change the washer part number SV01967 plumbcentre usually have them on shelf . . . or city plumbing...
  15. G

    Baxi 105e inlet manifold

    Good video but the 105e also had the filling loop connected to these valves . bit of an omit from baxi
  16. G

    Main 24 HE Condensing Boiler Error After Returning From Holiday

    Have you checked the two obvious thing s before calling someone gas is on at meter and pressure above one on boiler fault lights can sometimes be wrong
  17. G

    Gas Supply Pipe blocking crawlspace

    Having worked for BG and then cadent at various times over several decades what was this special key he used ? As this special key they needed you mention we were never supplied within anything like this
  18. G

    Gas Supply Pipe blocking crawlspace

    Yep especially with that yellow valve under floor it look like someone not transco/cadent has had the meter moved as a private job instead of paying the several hundred quid to them. Probably done many years ago . Yep and that earth bonding needs moving to the copper internals. . Bubble that...
  19. G

    Gas Supply Pipe blocking crawlspace

    can you put a pic up of the meter Its looking like someone in the past has done this service alteration by themself as opposed to paying the transporter