  1. ianmcd

    Trying to swap center receiver on combo boiler

    The loop is not required
  2. ianmcd

    Hive Mini installation

    That wont work Chris
  3. ianmcd

    Low Pressure Indicator on Airston Combi Boiler - advice please.

    Try bleeding the pump, large screw on the front just crack it open till water comes out you have air in the boiler
  4. ianmcd

    TRV on Hall Radiator

    You probably have or had a room thermostat in the hall, that is why no TRV, if you want one you will have to replace the complete valve
  5. ianmcd

    Can I fit a plume management kit on the flue myself?

    Hardly a small job to do it correctly, especially with that boiler
  6. ianmcd

    Baxi combi boiler - Honeywell to Hive thermostat

    Can you post a pic of the wiring at the boiler end please
  7. ianmcd

    Help with installing a Hive Mini to a Worcester Heatslave combi oil boiler with heat store

    yes but remember you will have to leave the ch on the prgrammer set to constantly on and let the hive take over
  8. ianmcd

    Vokera Excel 25 boiler and Hive Single

    no either way round will work , and to reitterate DO NOT make any links
  9. ianmcd

    Worcester Greenstar 432kHz noise?. SOLVED. Honeywell Gas Control Valve, faulty batch.

    Your boiler is resonating, it is still under warranty so get worcester out
  10. ianmcd

    ALDE COMPACT 3000

    https://www.manualslib.com/manual/944568/Alde-Compact-3000-92x.html?page=15
  11. ianmcd

    Replacing Potterton EP2 and Centaurstat 7 with Drayton Wiser

    Well as you have found out, the EP range were sold as a wiring centre and programmer built in to one, if you want to replace with a modern unit tou will have to create a new wiring centre to accomodate the connections you wont be able to do it otherwise
  12. ianmcd

    Prv leaking

    Nope
  13. ianmcd

    Three way valve and head - strange behaviour

    Just post a pic of the wiring in the wiring centre then we will know what you have
  14. ianmcd

    Prv leaking

    Lube the O ring and apply PTFE to the threads
  15. ianmcd

    Rad slow to heat up fully

    as @Madrab correctly says , you have a balancing issue, forget all the crap about changing boiler paramaters, water is like everything, it is lazy and will always travel the easiest path, so will happily circulate around the nearest small radiator than take the harder path to a large radiator...
  16. ianmcd

    Prv leaking

    PTFE will be cheaper
  17. ianmcd

    Loss of hot water pressure in vented cylinder thermal store system

    I think your blending valve is the problem, some do have filter screens, dont know that make but wouldnt do any harm to check, just close the blue handled valve and open a hot tap till the water stops and remove it and chech it to see
  18. ianmcd

    Salus RT500rf Thermostat - LED display shows room temperature too high (but isn't!)

    I know its not what you want to hear, but it is Salus, bin it and buy something decent, they are possibly the worst controls you could buy, they are absolutely dire