  1. T

    Ideal in loop!

    ignition control box on gas valve, common fault, changed **** loads.
  2. T

    IDEAL ISAR- NO CENTRAL HEATING

    we dont make that valve anymore, if you have seen any of the boilers this year you will know all copme with the grey head!!
  3. T

    IDEAL ICOS M3080 FLAME ERROR

    not far off there mate, could be a slow draining trap, due to lack of correct servicing or possibly the pcb, i wouldnt expext the pcb to fail on flame detection, if there is no spark from the board then defo pcb. part number 172490. i would definately remove the trap and clean out then check, if...
  4. T

    Warmsure

    erm.... i dont thinks so mate as my father works for bg and is very very high up in the company so what you said is complete bullshit, so please before typing your nonsense get your facts right!!!!!! and the failure rate on and isar/icos is 97% which actually beats worcestor bosch so stfu idiot...
  5. T

    Response gas pressure problem (UPDATED)

    the burners, electrodes are the same!! the burner is slightly different as it has a cap on the top thats all, our minimiser is a condensing boiler, but we did make a response that is also a condensing boiler, the response SE, the heat exchangers are the same on the response SE and the minimiser...
  6. T

    Warmsure

    hello, i work for ideal, and have for many years, if you feel that you are good enough and have the experience on fault finding then yes give it a go, warmsure is a relativly new company created by eaga and ideal boilers, if your looking for a carear in servicing and breakdowns then working for...
  7. T

    JOB INTERVIEW QUESTION FOR BOILER COMPANY

    Dan you are absolutely spot on there mate, we have as a company neglected you smaller installers, many of you fit other makes of boilers now, ok other manufacturers have clocks etc, but saunia duvall come on mate, they really are sh1te, potterton puma leaked even if you looked at it the wrong...
  8. T

    help old 'ideal' boiler British gas service has condemed it

    the same would apply then if you service a boiler passed a boiler and the seals seemed ok and in good condition, but 3 weeks later co leaked from the seals? ok they were the correct seals but they still leaked after you passed them.
  9. T

    Vokera Linea 28,No c/h or h/w

    common fault with the vokera was sticking gas valves it has the sit sigma 845 gas valve.01 code means lack of ignition, check with a u gauge on the inlet test point, run the boiler and if the u guage dips down when the boiler goes to ignite then the valve is opening, if not then check voltage on...
  10. T

    problem with ideal icos

    so why does the isar out sell most other boiler!! up here mate, its either worcester or ideal!!! mexico was a cracking boiler tho :) i have a greenstar at home and its ****e, always breaking down, had the flue seals replaced twice! oh and i didnt fit it before the **** take starts :oops:
  11. T

    help old 'ideal' boiler British gas service has condemed it

    because often the seals are no longer avialable, providing the seal makes an adequate seal and passes a co test around the boiler, ratio checks are ok the the boiler is no longer at risk, or dangerous. if a classic as a defected seal around the casing i can use an isar case seal, its the same...
  12. T

    problem with ideal icos

    thats right mate its quite common after the boiler has been in about 2 years as often lack of servicing can cause the electrode to loose is spark gap, regular servicing would pick this up, and electrode changed annually if needed. also the design of the spark gen has been altered recently so the...
  13. T

    JOB INTERVIEW QUESTION FOR BOILER COMPANY

    i have to agree with you there mate, the company is too bothered about this god damn warmfront lark, we as a company have seriously neglected the installers. we have major contracts with persimmons, wimpeys, and barratts, all which i, and the sales team have neglected. and to the mug thats says...
  14. T

    help old 'ideal' boiler British gas service has condemed it

    recent changes in the corgi regs state that it no longer has to be the exact seal from manufacturer, as long as the seal provides an adequate seal and no combustion leakage is present on a test of the case seals then the boiler can be repaired and passed. however the boiler is getting on in...
  15. T

    problem with ideal icos

    i work for ideal as an engineer and you dont need the pcb, all you need is a spark generator and lead, possibly the electrode, noisy igintion is caused on the icos of the either the sump being dry, ie boiler stat on max, or electrode lead touching the return pipe off the heat ex, but more often...
  16. T

    JOB INTERVIEW QUESTION FOR BOILER COMPANY

    i spend most of my days cleaning up after all you warmsure engineers!!!! we ideal engineers are disgusted at the poor standard of engineer we have been getting on these warmsure contracts. reading these post has proved very interesting as i have forwarded all the infomation to my board of...