  1. CountryFan

    Vaillant EcoTec Plus 428 constant cycling

    Is the motorised valve opening correctly?
  2. CountryFan

    Heating intermittent

    That should be the first thing to look at imo, especially given it’s been a week.
  3. CountryFan

    Vaillant EcoTec Plus 428 constant cycling

    Did you adjust any radiator valves? X400 is a cleaner, did you add any x100? Are all flow and return valves, including any magnetic filter ones fully open?
  4. CountryFan

    Hot water working but no heating (No fault detected)

    No problem whatsoever. Don't know, maybe they should have gone to Specsavers? :ROFLMAO:
  5. CountryFan

    Valiant ecoTEC plus 837 CH not going past 50

    Yep, that'll do it because it's a previous Vaillant control
  6. CountryFan

    What Waste Do I Need For 2 Appliances - Also Leaking Plastic Joints

    Check the seal for alignment, If good then either tighten more or replace the seal.
  7. CountryFan

    Valiant ecoTEC plus 837 CH not going past 50

    No reason for it to behave how it has then. I’ve not really encountered this before. I did have it once where I decommissioned an ebus thermostat, wouldn’t go above 50 and carried out a factory reset which got it working. Your new pcb should have sorted that though.
  8. CountryFan

    Flush siphon unit / filling valve too big for existing cistern?

    Yep, or change float valve for another ball type?
  9. CountryFan

    Flush siphon unit / filling valve too big for existing cistern?

    You may have to get a smaller syphon then. Is the fill valve height adjustable? Maybe increase the height slightly?
  10. CountryFan

    Light switch trapped wire

    Insulation tape or shrink tube?
  11. CountryFan

    Flush siphon unit / filling valve too big for existing cistern?

    Can you turn it so the float faces the right as you look at it?
  12. CountryFan

    Flush siphon unit / filling valve too big for existing cistern?

    Is it a similar size to the existing one? Photos of the cistern?
  13. CountryFan

    Hot water working but no heating (No fault detected)

    Hello David, and welcome to the forum. This would have been better in the plumbing section, but let’s not split hairs. Yes it’s been missed, you have a flow and return valve, and the return is closed. Open it and you should get your heating back on, attached a photo for clarity
  14. CountryFan

    Plastic pipe advice 10mm or 15mm

    If it currently runs ok on 10mm then probably stay the same. However, with plastic the internal pipe size bore is reduced when using the insert, so probably about 7mm or 8mm.
  15. CountryFan

    Valiant ecoTEC plus 837 CH not going past 50

    Not that I’m aware of. Which terminals was it wired to? 24v?
  16. CountryFan

    What Waste Do I Need For 2 Appliances - Also Leaking Plastic Joints

    I think you'll be surprised that it does. I have fitted many push fit (41mm) and solvent weld (43mm) into several 1.5" traps. I can't see anywhere on that drawing about 38.1mm
  17. CountryFan

    Valiant ecoTEC plus 837 CH not going past 50

    If they're bi-directional it won't matter.
  18. CountryFan

    Valiant ecoTEC plus 837 CH not going past 50

    Could be a fault with the diverter valve. Can't see it being a D code setting as the PCB was changed. Does the temperature shut off at 50?