  1. N

    Outside light spurred off socket

    Went to a job today to add a spur socket. Before doing the testing I noticed the outside light had been directly spurred off a socket in the kitchen. On the minor works cert for doing the IR test would it be ok to put 'LIM' in the box for testing P-N & explain in the agreed limitations box that...
  2. N

    where can you buy an isolator switch ?

    Yeah thats the one JohnD. The purple one is the easiest to fit.... :P
  3. N

    where can you buy an isolator switch ?

    ok thanks. I know MEM do one but I couldnt find it.
  4. N

    where can you buy an isolator switch ?

    Could someone advise me where you can buy the 100a isolator switches from that go between the electric meter & the CU (to isolate the CU without having to pull the main fuse). The ones I've seen on the TLC website are the ones that go in the CU.
  5. N

    RCD tripping problem again

    OK thanks, never tested an RCD directly onto it before. Do I disconnect the live busbar & test between the live load side on the RCD & earth? In my Meggers instructions, for testing on the auto sequence setting you have to put the red test lead on the live load terminal of the RCD & the green...
  6. N

    RCD tripping problem again

    A couple of weeks ago I posted on here about a nusiance 30mA RCD tripping problem (upstairs & downstairs sockets). I thought I found the problem, a double adaptor was faulty so I binned it. RCD tripping problem stopped. Now its started up again, so today I went through all the tests on the CU...
  7. N

    NIC DI assessment

    Can anyone give me a rough idea what happens on a NIC Domestic Installer Assessment. I've got one coming up & I've been reading up for about the last 6 months but still worried I havent taken it all in. :shock:
  8. N

    minor works cert

    Just carrying out my minor job today for NIC assessment. I've added an extra socket (spur). I've got 2 questions. 1. Where is says RCD on the cert. I've filled in the BS(EN) no. & the In bit. What do I put in the "type". There was nothing written on the RCD saying what type so I put in 63A...
  9. N

    Another RCD nusiance tripping question

    Just to update you. The tv & cable box were plugged into a double adaptor. I've removed the adaptor & tripping has stopped. Needless to say I have binned it. :)
  10. N

    Another RCD nusiance tripping question

    I'll see if I can borrow a PAT tester from somewhere. The RCD protects 2 cb's. The house ring circuit & the garage but there is nothing plugged in or switched on in the garage. Fell asleep watching tv the other night & woke up about 2am & all the power had gone off. The only thing that was...
  11. N

    Another RCD nusiance tripping question

    I carried out an IR test with my Megger. Unplugged everything in the house & the tests were >299M ohm
  12. N

    Another RCD nusiance tripping question

    Changed my CU about 2 months ago & did a complete test. (This is one of my assessment jobs). Unfortunately the whole house ring circuit is on 1 cb on the RCD side. Over the last week the RCD has been tripping now & again. It does it mainly when the tv & cable box are switched on (washing...
  13. N

    16mm meter tails & DNO

    When I phoned Central Networks they said that this wasnt their responsibility. The women read out a list of things that they were responsible for, things like underground cables, substations etc. When I phoned British Gas the women I spoke to just wanted my ££££ & that was that. Cheers for...
  14. N

    16mm meter tails & DNO

    Yeah, good point. I was going by the label on the side of the fuse. It looks like a proper label that should be there. I've worked my max demand out to be 56A so the 16mm tails would be ok anyway. Its just the fuse thats debatable.
  15. N

    16mm meter tails & DNO

    Got the NIC bloke coming out for an assessment soon after changing my CU & noticed in my meter box I've got a 100A main fuse & 16mm tails. Phoned Central Networks who said I need to speak to the metering dept at my electric supplier (BG). Managed to get to speak to someone who was only...
  16. N

    Checklist for different jobs

    ok, thats good then :D
  17. N

    Checklist for different jobs

    Has anyone got a checklist they use each time they go to look at a job before quoting.
  18. N

    NICEIC Domestic Installers

    scousespark - I'm not for one minute thinking of going for AC or thinking a 5 day course would have prepared me for commercial/industrial work. I was just stating a fact. All I'm concerned about at the moment is passing my assessment & getting my DI approval.
  19. N

    Adding a spur, but no supp bonding

    The spur I am adding is in her bedroom.
  20. N

    Adding a spur, but no supp bonding

    Adding a spur to a socket at my mums, but she has no Supp bonding. Am I am correct in saying that I dont need to carry this out, as the job I'm doing is not related to the bathroom ?