  1. G

    2 different boilers on CH system replacement quotes

    A lot will depend on your incoming water main, if you have good flow and pressure the 42CDi will give you great hot water and a very good shower too ive fitted lots of them and personally think they're fantastic boilers.
  2. G

    New Boiler installation

    that really would be 1 billion dollars then!
  3. G

    Condensate pipe, run inside?

    outside is ok providing its protected against freezing, but only run it outside if that's the last resort.
  4. G

    Is there any advantage in insulating 22mm Hep2o pipe?

    lag the pipe first then secure it with some galband, that's what i do for pipes that should be lagged http://www.screwfix.com/p/galvanised-band-12mm-x-10m/18298
  5. G

    Suspect lead gas pipe dangling from kitchen ceiling

    no need to classify it at all IMO by the time you've spent filling out the paper work etc. you could've just capped it and been on your way!
  6. G

    worcester bosch highflow 400 rsf stopped working

    you might need to top up the pressure in the system, what does the pressure gauge say on the front of the boiler? is it down in the red? if so, you'll need to top it up. you may have a standard filling loop, or an internal one.
  7. G

    When hot water gets to set temp what should happen?

    your megaflow will have a hot water thermostat fitted as part of the unit, once it's satisfied it should shut the hot water 2 port valve, assuming nothing else is calling for heat, then the boiler will shut down too. if you have no room stat and you have your heating on then the heating valve...
  8. G

    Whining from central heating - driving us crazy

    if the lockshield valve on a radiator is cut right down it can make the noise you're describing, try opening it up a bit more and see if it makes a difference
  9. G

    Flues and pipework

    baxi did a condensing back boiler that had a concentric flue liner to go down the chimney. it had a built in condensate pump im not sure if they still make them anymore though
  10. G

    Feel for this guy.

    most plumbers have been in a similar situation, i know i have! first thing he needed to do was to open all the other taps and take the pressure off. if he couldn't get a fitting on set about flattening the pipe. although that's easy for me to say in front of my pc at home!
  11. G

    Compression fittings.

    in glasgow they still wrap joints with hemp
  12. G

    Tool for a broken pavement stop tap?

    one like this? stopcock multi key, available in all good plumbers merchants (and some bad ones too)
  13. G

    vertical radiator orientation

    vertical radiators can be a pain to balance, what works sometimes is shutting down the lockshield almost fully, this then slows the water down and lets it circulate better
  14. G

    How to avoid a bad plumber

    the ones i've ever spoken to want your gas safe number before they'll speak to you
  15. G

    Carbon monoxide alarm from gas fire

    i worked for Transco a good few years back, we were told just to isolate any appliances suspected of spilling CO at class them as ID "to be on the safe side" it could've changed right enough but if i was called out i would cut it off, make it safe and inform the user to get it checked...
  16. G

    Roaring water!

    it could be quite possible that your main stop cock was only opened half way to start with, the bathroom fitters have come in, turned off the water then turned it back on fully.
  17. G

    Help with choice of bath taps.

    if you have 2 different pressures going they won't mix very well. your cold main pressure will 'push' the weaker hot out the way and not mix unless you cut the cold down. it'll be like cracking a safe, you'll be turning down the cold a tiny bit at a time to get the right mix. seperate taps, or...
  18. G

    Warning notice for new boiler and gas supply turned off

    have a look through the installation manual (assuming they left you one) i had a quick look online and found this on page 19 of the installation instructions: • Connect a gas supply pipe of not less than 15 mm diameter to the copper tail. • Tighten all connections. (Ensure the gas supply...
  19. G

    Radiator fitting

    never seen a mini TRV but they do come in different sizes depending on the manufacturers, Drayton TRV4 are pretty slim and are good quality you could put the TRV on the other side if there's more room