  1. B

    Thermostat doesn't turn boiler off

    I know what's wrong with this one!! (been caught myself) you MUST remove the 24v control link on the boiler PCB (otherwise it will operate 24hrs as this one is doing!) :wink:
  2. B

    Remaha Avanta boiler

    But just a point - even filthy system water should not be able to leak out under the boiler onto your floor so I am really confused now! :?
  3. B

    Thermostat doesn't turn boiler off

    Is it a Thermostat or a Compensator control?? perhaps some pics would clarify?
  4. B

    Underfloor Heating Pump Wiring - Wrong?

    I suspect that what you are calling wrong is actually right, because what you propose will cause the pump to get a back feed and run against a closed motorised valve when the other circuit calls for heat :wink:
  5. B

    Remeha Avanta Plus 28c leak...

    And don't blame your boiler for a leak that isn't even on the Boiler!! :lol: :roll:
  6. B

    Oil boiler spares

    Might be better if the boiler shell is still sound, to obtain a new Burner such as a EOGB X400 series?? :wink:
  7. B

    Split oil tank advice

    I have used Soap to stem a leak on a brim full 2500 tank the leak was at the bottom too!! it stopped the leak dead for 2 weeks giving the client time to have a new tank fitted in a "compliant position" elsewhere if the tank is not evenly supported it can easily crack, so make sure your new...
  8. B

    Can someone recommend a pump

    How about a Grundfos Magna 1 25/60-180 ?? can't say I'm a fan though! :wink:
  9. B

    Oil boiler spares

    No parts are available for the Hojspanding burner fitted to the Mk 1 I managed to get a coupling for a Sterling to fit one last week but a HP oil line will prove impossible, have you looked at using a HP flex 1/8" bsp (as used for oil pressure gauges?? with some 1/8" sockets you should be able...
  10. B

    Notifying Gas Safe of boiler install

    I did a notification last week, the Client recieved the certificate within 4 Days so at the moment they are getting them out pretty quickly - are you sure your installer is Registered/Qualified as a notification really only takes 2 minutes! :?
  11. B

    Lifting my heavy old cast iron radiator! Help please...

    In all seriousness you will need at least 3 more able bodied persons to lift that back in position and secure it- it is simply a matter of man power! :roll:
  12. B

    Oil boiler failt

    My money is on the Solenoid Coil, or Capacitor :wink:
  13. B

    Leaking SIKA Flow Switch

    This type of switch is renowned for leaking! your method statement looks fine but two points TURN OFF the cold water main, then open up a hot tap to discharge the trapped water under pressure before starting work, secondly make sure that the new switch is in exactly the same orientation (there...
  14. B

    Fire valve for oil boilers

    Building regs require and have always required a remote acting fire valve be fitted so yes you will have to fit one such as a teddington KBB (other approved types are available) I would remove the exisitng non- conforming valve to avoid future problems! :wink:
  15. B

    flushing mini-disaster!

    Connect the flushing equipment to your system using appropriate fittings :lol:
  16. B

    Inter 2011 Burner and Danfoss BFP21L3 Pump 3 Plumbers Later

    It occurs to me that no one has checked the in-line oil filters, partial blockage of oil filters will cause the symptoms you describe If you need a help send me a personal message - my company are based in Suffolk and specialise in service & repair (OFTEC) registered (for what it is worth!)...
  17. B

    Potterton Myson Boiler

    Tony - a Gas Train is the term used to describe valves, governors and safety devices making up the control group supplying fuel gas to the burner. The Fan is not part of the gas train - however it is still not for tnkering with by an incompetent (someone who has not PROVED competence is...
  18. B

    Boiler service/check

    We charge anything from £78 - to £112 +vat & parts - depending on what the boiler is from a wall hung heat only to a gas fire back boiler or a conensing oil combi !! Why are you "fishing" ? :?
  19. B

    Best External Oil Boiler?

    Another Vote for Hounsfield Boilers. When Andrew Hounsfield decided to make an external boiler he spoke to people in the industry that install AND service (people like me!) I advised him that a good external boiler would have a "True" balanced flue - not just a low level discharge ( as this is...
  20. B

    Any guesses? Random pipe coming out of the wall..!

    it is a steel pipe - my guess is GAS :!: