    Baxi 105e no central heating

    No one is going to advise you other than you need to get a Registered Gas Installer in working on gas appliances unregistered is unwise :wink:
  2. B

    Thermecon oil boiler issues

    To the right hand side of the pump is a grey plastic knob, this is a manual air vent unscrew this a few turns until it hisses and then water will come out (careful as it will be very hot! turn off once water flows freely all should then be OK :wink:
  3. B

    Expensive Plumber??

    Lets hope your "bodger"?? plumber is not one us reading this, he will certainly be able to work out who you are ......... think before you type is my motto!! :roll:
  4. B

    heating valve replacement motors

    It might be worth speaking to MHG ( The Mann B&W also made the Strata I & II boilers - MHG seem to be able to get spares for these at much lower prices than other agents (with similar names!!) :wink:
  5. B

    UPS2 pump failure

    MrDuck I cannot say if it is good or bad, but we are currently fitting Wilo products based on customer service and parts for old pumps availlability :wink:
  6. B

    UPS2 pump failure

    My Company no longer use Grundfos pumps largely due to early obsolescence of heads for Commercial pumps and due to many problems with the UPS2 range :cry:
  7. B

    wallstar boiler keeps locking out & getting air in the p

    Most Wallstars are fitted in the wall higher than the oil tank, (I have only worked on one that was installed at ground height) assuming yours is fitted 5ft approx up the wall, then a non return valve must be fitted, HRM supply a fire valve and NRV combined, however you may have a NRV fitted...
  8. B

    GRUNDFOS Pump Failure.....suggestions

    Before ripping out your pump, have you checked that there is voltage at the pump (230vac) between the L & N connections on the pump measured using a multimeter??? :?
  9. B

    Y plan setup question

    In that scenario I would have fitted some sort of vent to the Primary flow connection at the cylinder :wink:
  10. B

    Rayburn flue door

    Yes a stainless steel plate with gasket and fixing screw is available from chimney specialist wholesalers you have to stitch drill a suitably sized hole in the existing flue pipe, the new cover/gasket covers the hole to leave an inspection hatch for future use :wink:
  11. B

    Heatslave strange diverter valve problem

    The Valve should be up (Spring relaxed) for HW, and down (Spring compressed) for CH are you saying that the radiators are getting hot even though the controls are not calling for heat?
  12. B

    underfloor heating manifold

    Looking at the picture, when you switch the Pump and mixing valve to the RHS, the control knob will be pointing towards the wall, will threre be sufficient clearance between the manifold and the wall to fit it all in?? adjustment of the mixing valve may be difficult in this orientation :?
  13. B

    underfloor heating manifold

    Looking at the picture, when you switch the Pump and mixing valve to the RHS, the control knob will be pointing towards the wall, will threre be sufficient clearance between the manifold and the wall to fit it all in?? adjustment of the mixing valve may be difficult in this orientation :?
  14. B

    Cast iron rad

    EDIT those pipes look more like 3/4" steel :wink:
  15. B

    Cast iron rad

    That rad looks like it is on a single pipe system, you will probably want to plug the two pipes where they join the main loop so a drain down is likely unless you can freeze 2" steel? other wise a freeze on the 1/2"? pipes and remove at suitable fitting and plug :wink:
  16. B

    Y PLAN SUNDIAL.

    A time clock is a single channel unit so the link is there to ensure that both hot water and heating operate on the time switch, as a programmer is 2 channel, the link has to be cut so that each channel only operates it's dedicated duty :wink:
  17. B

    Megaflow recharge interval

    When a Megaflo is installed there is a 22mm branch near the PRV, this is the "Balanced Cold" connection, however many installers neglect to use this port and so the Cold taps are at higher pressure than the "controlled Hot Water" the first place I would look is any Shower mixing valves - it...
  18. B

    No hot water

    Personally I'd be taking out the pump to make sure that it is running and that the impeller hasn't broken off :wink:
  19. B

    boiler noise

    Also - why the hell would you have your heating coming on in AUGUST!! ? :shock: :shock:
  20. B

    Ideal HE15 boiler advice

    As you say the HW valve was stuck open, I suspect that you will need to replace the synchonous motor in the powerhead these can be obtained for around £10 :wink: