  1. T

    PFC on a TT system

    sorry Taylorwocities, you got there just before me. Least i know for future reference that thsi is what i wirte in. Thanks
  2. T

    PFC on a TT system

    Yes I know that! My thoughts are that if there is a PEFC or PSFC then there is only 11A runnign down the live. This is therefore not enough to trip a ring breaker. Therefore the need for RCD's. Main point is that I have never done a TT suppply and I am using his house as practice. was...
  3. T

    PFC on a TT system

    Hi, I have been round my friends house as he has a TT system and I have never worked on these installations before. (yeah yeah, pathetic I am! lol) Whilst doing the PFC the result was 11 Amps. Is this correct for a TT system? I am guessing it is as the Ze was 20.9 ohms. I was just...
  4. T

    Ze on a light circuit

    Just a quick easy one for clarification :) when measuring the Zs value on a light circuit they normally say measure at the extremity as this is where it will be highest. However, I have a situation where my highest reading is on the second loop in loop out ceiling rose (out of 5). This...
  5. T

    Maximum lenght of tails from isolation switch

    problem with SWA is that you can not terminate it correctly in the usual new consumer units that people buy from various sheds. the last thing they want is a new consumer unit with a metal clad box sitting right near it. personally I wouldnt use SWA for running cables inside the house...
  6. T

    safety zones within kitchen

    thanks for all the opinions. I think everyone is agreed, the zones are good to know about and at least hopefully preventing dodgy angled cable runs. But as we know, the average bloke in the street would have no idea and could quite happily bash a nail either above a socket or horizontally...
  7. T

    safety zones within kitchen

    Hi, can i ask for a number of opinions on this small matter :o). why is it that safety zones are ran down each side of the wall and horizontally/ vertically from all sockets? if you are fitting kitchen wall units against a back wall you always fasten the units right in the corner (or at...
  8. T

    Consumer Units.

    :lol: corect, but im just trying to see opinions on how many circuits can be on one rcd before it doesnt comply with 17th edition. but i guess thats the probs with the wiring regs, they cant lay it all out in black and white (even though they have :D ) and it still is open to individual...
  9. T

    Old DNO supply

    well i think he has learned his lesson to pay when the job is complete, not half way thru, its electricians job to pay and supply all parts, well thats my theory anyhow? so, is it now illegal to have both live and neutral fused? is it upto DNO to change them?
  10. T

    Consumer Units.

    thanks EC. so simple question then open to one and all, two circuits in a very small house, poor person only has one room lol. does the light and sockets on one RCD meet 17th edition?
  11. T

    Consumer Units.

    so, you can never fully cover nuisance tripping, well unless you go to RCBO's. therefore is it still not correct in saying that if all circuits are covered by a RCD then it does meet (in a crappy sort of way) 17th edition? you have a house with one ring circuit (sockets) and 1 radial (lights)...
  12. T

    Consumer Units.

    Hi BAS, I aint got a regs book to hand so can you please qoute 314.1 :).
  13. T

    Old DNO supply

    well i can ask the lad who owns the property to take a pic but i think he is only down there on weekends so it wont be till next week unfortunatelly. any advice on the dno etc?
  14. T

    Consumer Units.

    from what i gather you could have a consumer unit with 12 MCB's in all covered with one RCD and it still meets the 17th edition, the problem with that is the nuisance tripping. if one circuit goes it takes out the whole house. therefore with only a few circuits you still have the same...
  15. T

    Old DNO supply

    Hi, I was wondering if someone can give me some advice, The answer (IMO) is obvious but just wanted to know for certain. I know an old property that is getting rewired and the main incoming fuse is one of these in a old cast iron box and both the live and neutral are both fused. there is also...
  16. T

    Mira Excel shower and Worcester 24i bolier - Please help

    many thanks for all your replies :o), well i spoke to an old friend last night who is now a retired plumber. he stated the same thing that there is no point in spending the extra money on fitting a expansion vessel. He also said that you dont get an amazing pressure with mixer showers as well...
  17. T

    Mira Excel shower and Worcester 24i bolier - Please help

    Many thanks for the answer :), that has hit somethign in my little pea brain as why we need it when there is all ready a large expansion vessel in there. i take it the large one is for the heating system though :). one question is tho, if i aint got one on at present and it has been working...
  18. T

    Mira Excel shower and Worcester 24i bolier - Please help

    thanks, but why does it state in the installation manual that you require a mini expansion vessel on your cold water pipe to the boiler? im not that into boilers etc.
  19. T

    Mira Excel shower and Worcester 24i bolier - Please help

    Hi there, hopefully one of you wonderful people can help me understand the problem i think i have. I have fitted a mira excel built in shower and i have very little pressure and also the temperature is crap to put it politely. I have read the instruction manual and it says that a mini...
  20. T

    Electric Hob

    I cant remember exactly what is written, I think all it states in one box is power rating and cable, power rating it has 7800W and then under that it has 2.5mm. I can check and confirm later today if need be?? I did have look at the connection point as knew straight away it should be bigger...