  1. L

    Instant water heater

    This may offer a guide http://www.tlc-direct.co.uk/Technical/Charts/VoltageDrop.html But other factors may also affect cable size
  2. L

    Two spurs for lighting from a double socket

    And don't forget to notify LABC before you commence work :wink:
  3. L

    how to connect an emergency stop to a 3phase motor

    The best way would be to use a safety relay, try searching Farnell or RS components for one. If you interupt the coil of the contactor using the e-stop, you may have issues about automatic startup when the e-stop is reset. However one way of fixing this issue is by placing the e-stop in series...
  4. L

    Part P and Park Homes.

    Interesting points being made. What about all other parts of the Building Regulations? Do caravans need to comply with those? Regards
  5. L

    Multi testers

    Surely you can work out touch voltage multiplying the RCD rating by the Zs of the circuit :?
  6. L

    Wiring a Shed for low load work

    Here is some usefull info for shed wiring http://www2.theiet.org/Publish/WireRegs/WiringMatters/Documents/Issue16/2005_16_autumn_wiring_matters_electrical_installations_outdoors.pdf
  7. L

    PAT, Testing Equipment.

    Will a loop impedance test be adequate? Regards
  8. L

    2 fcu's from single socket

    Why spur from the socket? Cant you break, then extend the ring at that socket to include the extra FCU's? Regards EDITED: oops sorry davy, I see you already said that :)
  9. L

    megger wandering lead

    If your meter has 4mm sockets then there is an adapter on ebay for using a mains extension lead as a wander lead. There is also a 50M wander lead for sale but it costs 75quid :shock: I think you need to search for 'wander lead' as well as 'wandering lead' regards
  10. L

    Can a socket be added to a lighting circuit?

    I disagree that its FAR beyond regs as it can be isolated at the CU. You could argue that a 13A socket on a 5A circuit is beyond regs. But I must admit the wiring into an FCU idea is definately best. EDITED: Local isolation means you wont damage the booster during insulation testing (if it...
  11. L

    Can a socket be added to a lighting circuit?

    Why put a socket in the loft? Just cut the plug off the booster and wire it into a junction box on the light circuit. No need for additional fuse protection as it is on a 5A circuit anyway
  12. L

    MCB not tripping!?

    If all the lights are on 1 circuit then maybe you have a loose connection at a ceiling rose. You could turn off the power and have a look by pulling on wires. There will be 3 rows of terminals and the ones at fault will be 3 browns( or reds), or the terminal with 2 blues(or blacks). Thats not...
  13. L

    help needed with nylon gland and external JB...

    As long as you have back nuts for the gland you are ok. Sometimes they are sold seperately
  14. L

    Cable routing

    Your local building control should appoint someone to oversee the rewire. That person will give you all the info you need
  15. L

    Electric shower

    Point taken If I see anymore posts that need answering I shall reply with "Leave it well alone you monkey"
  16. L

    Electric shower

    Dude, I was taking the p155 because the I found the spur issue funny. :roll:
  17. L

    Electric shower

    Its probably easier to run it separate if the consumer unit is there in the cloakroom PS don't forget the the label warning of 2 different wire colours :D
  18. L

    C&G 2391 results..

    Yes http://groups.msn.com/SparkyHeaven/frontpage.msnw