    dont think there was any specific statemant but if the boiler is in a cupbard without ventilation then the obviously the pcb will get too hot and fry circuits :cry: and also alot of the jobs i goto are locking on overheat normally due to pump not wired back to boiler or no bypass :roll...
  2. G

    Suprima - Expert Witness Statements Requested

    :D Personally think you are wasting your time ! but if you do take it further i hope you can prove the boiler has been installed correctly and serviced annually :roll: as approx 70 % of the Watchdog jobs i goto cannot prove service history and boiler normally has one or two...
  3. G

    Decommissioning a BBU

    phone baxi 08706 096 096
  4. G

    Baxi Platinum installers near Chester

    must get more points from them :D
  5. G

    Decommissioning a BBU

    Using a back boiler fire when the boiler is decomisioned is not permitted as BBU states (back boiler Unit) is a complete appliance and you cannot use half of an appliance if the other half has been decomissioned as the flue ways pass through the back boiler :? i had this same argument some...
  6. G

    baxi bahama 100 ignites then cuts out

    i personally always recommend them on this boiler as magnetite is a real problem for the flow switches :?
  7. G

    baxi bahama 100 ignites then cuts out

    no wot happens is magnetite gets attracted to the magnet in the flow switch causing it to fail but it can quite easily get circulated around by the pump causing intermittent faults :D
  8. G

    baxi bahama 100 ignites then cuts out

    always flow switch on these cant believe baxpoti didnt put that as they are pants :?
  9. G

    Whistling Boiler

    have you seen how old this thread is i bet half the people who posted this are dead :?
  10. G

    powermax 155 horstman clock

    i think they are pants :? but only thing could be causing premature failure is power spikes or such as like try fitting a filter to power supply to boiler :D
  11. G

    Range Powermax 140 - Central Heating

    the programmers are crap on these do the red lights look dimmer than normal ?
  12. G

    is it the pump or the divertervalve(potterton suprima 30L)

    and stop shouting :) if anything it would be diverter stopping it firing up :shock:
  13. G

    baxpoti.. baxi 100HE plus problems.

    Tony is right if resistor goes in Lead it would be a permanent failure and it sounds like the air to gas ratio mixture is out of calobration which means putting in a new gas valve as you cannot adjust them :? also check that the burner is seated properly as i asssume you fitted anew one and...
  14. G

    Watchdog program on Potterton PCB's

    Exactly namsag thats my point most of the boilers im going out to fix free of charge are 7 or 8 years old in upboards with no ventilation :? and yes Gas4you in my experience gas valves havent caused too many problems on the Suprima :roll:
  15. G

    Watchdog program on Potterton PCB's

    nearly all of those were safety issues which had to be done as they could have been sued :? like we did with the Olympic problem :roll:
  16. G

    Watchdog program on Potterton PCB's

    Wot like us going out and fixing them free of charge even if they are 10 years old never been serviced and not wired up correctly :? oh yes we are doin that :) how many other manafacturers would be doing that :shock:
  17. G

    Watchdog program on Potterton PCB's

    Profile and Prima are one of the most reliable boilers ever made so i disagree about the pcbs on them :? But the rest you might have a point :D
  18. G

    Watchdog program on Potterton PCB's

    I agree with you the so called expert they had on the program said that a pcb should last at least 5 to 10 years and the majority that i go to are over 5 years so they are contadicting themselves :) yes it is a weak point of the boiler but so is the pcb on most boilers but because the...
  19. G

    Baxi Combi 130 HE (No CH)

    Intellistat is a pain in the arse especially when you are trying to test the system as for some reason it can take upto 5 mins to tell the boiler to come on :)
  20. G

    Baxi Barcelona

    Definately sounds more like combustion door seals have burnt out to me :D