  1. L

    Room Stat Problems

    HI replace the cyl stat.it is probably stuck .
  2. L

    Worchester Bosch 28CDi

    HI pressure when cold 1-1.5 bar when hot 1.5-2 bar.if the system is not treated chemically then try adding sludge remover then inhibitor.
  3. L

    Vaillant Turbomax Pro 28e slow to heat and hard to balance

    HI boiler not big enough. 14 rads x average 2 kw (with heat loss etc )=28 kw boiler has to be atleast 32 kw .so you can not balance the rads.your boiler is working very hard to supply all the rads . FED UP OF COWBOYS ? TRY INDIANS .
  4. L

    Vaillant luke warm bath tap

    HI I would agree with hootingowl.24kw is not big enough for hw and this diferrence can be seen in winter.
  5. L

    vaillant system boiler loosing pressure

    HI big house at least 22 rads pipes running into celing and into wall (done by someone else ) :(
  6. L

    vaillant system boiler loosing pressure

    HI wonder if anyone can help vaillant system boiler keeps loosing pressure.looses about 1.5 bar in just two days. 1.it is unvented system 2.new boiler only used about once a week (empty property) 3.no water leak visible at the overflow
  7. L

    Combi boiler pressure keeps rising

    HI secondary heat exchanger letting by
  8. L

    ravenheat csi85t boiler

    HI ch sensor could be faulty
  9. L

    Ravenheat RSF 820/20 T Part Identification

    HI hot water expansion vessel ?
  10. L

    no heating and hot water

    HI could be many things 1.hw sensor 2.ch sensor 3.air pressure switch 4.flueways blocked 5.fan faulty 6...... :(
  11. L

    Push Connector leaks!

    HI A picture would be good. :)
  12. L

    Gloworm boiler

    HI look in the manual or search internet for the manual.
  13. L

    leaky pipe at filling loop.

    HI Replace the filling loop. :D
  14. L

    shower tray help

    HI easy. 1.regrout or fill the the gaps between tiles 2.remove the old silicone completely 3.use new silicone where the tiles meet the tray and i guarantee it wont leak. :D FED UP OF COWBOYS ? TRY INDIANS.
  15. L

    Fireplace Rebate help needed

    HI gazfen you should not give advice to others if you are not aware or the rules.wood is not allowed when is so close.
  16. L

    connecting on to lead waiste pipes

    HI sorry but i prefer compression waste fitting before the cast iron soil pipe.
  17. L

    extra long curved chrome shower curtain rail

    HI if fitting curved rail then the middle ceiling support is very important.i am pretty sure you will be able to buy any rail size from your local merchants.
  18. L

    Hearing next door's water hammer?

    HI did lots of these.most likely (if fitted) brass float valve in the loft .cold feed tank .
  19. L

    leak through bedroom ceiling

    HI few months ago i did my fascia boards.and also cleaned my roof tiles but since then when it rains occasionaly water penetrates through and comes through bedroom ceiling. 1.there is no tiles cracked 2.it leaks where nails are through the felt 3.when i move the nail rain water seems to...
  20. L

    Biasi 24S Hot water problem.

    HI 1.is the control knob free ? damaged ? 2.hw sensor faulty 3.microswitch faulty 4.dhw diaphragm damaged all above common faults good luck