  1. spacethegas

    vaillant turbomax 242/282 problems

    the pump flow switch will not require replacing, just tubes clearing (if necessary) as was explained.
  2. spacethegas

    potterson boiler

    :?: when the flowswitch assy arrives you are going to test whether it is required ? or you have tested, found the flowswitch to be suspect & will attempt to replace it ?
  3. spacethegas

    No Heating/Hot Water

    you will be lucky if it lasts a day or two.
  4. spacethegas

    Boiler above Hot Cylinder

    wherever convenient.
  5. spacethegas

    Boiler help pleease

    on a combi or system boiler.
  6. spacethegas

    Where is the pressure valve on my Heatline Compact Boiler?!

    so thats the excuse you give when the customer catches you rifling through her knicker drawer.:lol:
  7. spacethegas

    Sabre 24 combi boiler - fluctuating hot water temperature

    it sounds like it wasn't flushed & chemically treated properly when the boiler was originally installed. this is very common when a cheap boiler is cheaply installed. i'm not necessarily putting yours in this bracket, but it sounds an ideal candidate.
  8. spacethegas

    Noisy System

    the cold feed (cf) you have drawn from your feed & expansion (f&e) tank down to your boiler. i would guess the open vent (ov) comes from the bend (on the diagram) just before the pump & terminates over the f&e tank ? DH asked for the static head distance ? as you have no trvs a bypass...
  9. spacethegas

    Problem with Glow-worm Ultracom 38Cxi, possibly....

    it sounds like your radiators need balancing. look here. http://www.diydata.com/projects/centralheating/balancing/radiator_balancing.php
  10. spacethegas

    Boiler help pleease

    take a look at various boiler installation & service instructions. they generally list a sequence of events. also checking through the fault finding procedures will help. theres plenty here to get you going. http://www.partsarena.com/baxi/ flow switches are generally on the water...
  11. spacethegas

    What fittings?

    i'm being somewhat pedantic here you might think, but copper/brass & galvanised should not be directly joined together on water pipework. a dielectric or nylon/plastic fitting should be used to reduce the steel corroding. then this brings up the question of supplementary bonding i suppose.
  12. spacethegas

    vaillant boiler - problem with heating

    the 'cure' will be too involved for diy.
  13. spacethegas

    on off on problems

    sorry it just gives me a headache trying to read that.
  14. spacethegas

    alpha 240x

    the gland/stuffing box/'o' ring needs replacing.
  15. spacethegas

    Insulating under a bath

    i mentioned it cause i stuffed mine when i fitted it 4 years ago. probably worth a look behind the panel at some point.
  16. spacethegas

    Noisy System

    the two bleed points could do with replacing with aavs. the system needs a bypass. are trvs fitted ? a lot depends on exactly where the cf & ov are on the system. is the noise constant, now & again, only when ch on ?
  17. spacethegas

    Insulating under a bath

    please elaborate. i'm always prepared to learn.
  18. spacethegas

    Insulating under a bath

    helps keep the bath hot longer, especially with steel bath.