    Worcester Bosch 28Si II fault

    Probably because the Si range have plenty of PCB problems.
  2. past3bar

    Halstead Ace High boiler

    Probably the CH thermistor needs replacing.
  3. past3bar

    Cold Radiators Conundrum

    Adam are you sure the rads are turned on? Do the upstairs rads have thermostatic valves? If so try taking the heads off by unscrewing the metal collar. Push the pins in and out with the flat of a spanner. Give the side of the valve a sharp tap or if you are really brave put a towel on the...
  4. past3bar

    Best boiler for around £500?

    Iwouldn't touch the Baxi with a bargepole but if you are in Bury go a few miles up the road to Burnley Plumbing Supplies and they will beat anybody on the Biasi price. Ive fit loads of these without problems. spend a bit extra & buy a magnaclean , well worth the extra.
  5. past3bar

    HELP PLEASE!!!! NEXT DOORS FLUE IS MAKING A LOUD BANG

    Is the boiler a Ideal Response?
  6. past3bar

    Baxi Ignition problem

    I would replace the plastic sensing tubes which become hard and split easily on this model. Be careful you don't lose the metal pipe into the back of the casing when pushing up from the bottom. It is an inexpensive exercise which can overcome ignition problems with this boiler.
  7. past3bar

    Baxi Combi 80e, HELP!!

    Are you sure your not just turning off one of the flow/return/cold mains isolators instead of the filling loop? I know it sounds simple but everyone makes mistakes!
  8. past3bar

    Boiler cutting out - pleases help!!

    I encountered a 19/24 Cbi regularly going to lock out recently which was fitted to an open vented system (approx 4 years) and had previously worked fine. Someone had talked them into a new PCB but no improvement. The problem was the APS pipes were perished and cracked (but not obvious till I...
  9. past3bar

    Worcester Greenstar Junior Install - aaarrrgh!!!!

    Fit loads of Greenstar 24/28i juniors as all my customers seem to read mags they advertise in . I've suffered all the problems you have and now you have to practically build the thing (condensate syphon etc). Time will tell on reliability but near enough every week i replace a board on the old...
  10. past3bar

    Wickes 90 (Halstead Finest) CH problem

    Thanks i'll try those tips tommorrow
  11. past3bar

    Wickes 90 (Halstead Finest) CH problem

    Boiler operates correctly in DHW mode. In CH mode it starts ignition sequence ,fires ,runs for approx 30 seconds then gas valve shuts down pump overrun continues then boiler goes into anti cycle mode for 3 mins. It will fire normally in dhw and provide endless hot water or start again if...
  12. past3bar

    Problems with Vented Thermal Store

    There are no markings on the cylinder except a sticker indicating Fernox Protector was added in 2002. (When I think system was installed) I thought the flow and return temps were similar because I drained the offending rads then opened the valves to check and possibly clear any minor blockage...
  13. past3bar

    Problems with Vented Thermal Store

    Problem where some radiators do not get hot on system with Worcester CBi 19/24? heat only boiler. Thermal store has 2 pumps one for primary and one for ch with by-pass valve fitted. Checked offending rads- trv's fitted but valves checked and no evidence of sticking or blockages (ptfe etc)...