  7. mehran

    30kW System Boiler Choice

    right... I going to back up Alec here a little bit. in reality there will be two figures at work here. 1, the actual heat loss at any give outside temperature and 2, the kw output need to equal and then over come the heat loss to heat the house to any given temp. if you use...
  8. Untitled

    Untitled

  9. Untitled

    Untitled

  10. Untitled

    Untitled

  11. mehran

    Johnward & VicVapour

    getting better ericmark :lol: but have you tried to get a vc4013 valve in UK? Dont fancy flying over to Syria. At any rate if you wire up as you suggest, I you would not be able to time the hot water, It would keep the cylinder hot 24hr a day 7days a week 365 days a year. Though I do some...
  12. mehran

    Johnward & VicVapour

    Jez, the wc part is useful in system with two 2-port valves as you you can still time the dhw and though not stated by eco you can keep an intergas a combi. Which gives can give you two different dhw temperature and a low temp ch temp.
  13. mehran

    Johnward & VicVapour

    I think EFLImpudence posting that picture sums up the problem quite nicely... you can't wire up a modern boiler with-out permanent live and the pump is directly wired to the boiler nowadays for pump over run... if you were the sparky on site and followed that wiring diagram I would need to...
  14. mehran

    Johnward & VicVapour

    Makes perfect sense to me, he wants to dual flow temperature system. One flow temperature for the boiler to CH and another for the DHW. The problem with you electric lads is you dont know why we want to do the thing we do so you dont have the background.
  15. mehran

    any central heating engineers near Stockton, Cleveland?

    I work in Cleveland, you can find my number in my profile.
  16. Untitled

    Untitled

  17. Untitled

    Untitled

  18. mehran

    3 band A combis needed wheres Best price Anyone?

    Transam is a bit of a boiler pimp, He likes them cheap and dirty :lol: Lets hope he wears rubber gloves when he installs them... Btw I would look in his profile at the ravenheat heat exchangers. Anyway atleast you will have spare parts when the first one goes tits up. You can rob it for bits...
  19. mehran

    Converting a vented cylinder with coil HE to use PHE

    Replacing the cylinder is easier... But If you did want to use a Phe then you not put it on the mains but put it on the cold feed to the cylinder pumping the heated water into the cylinder out let.
  20. mehran

    3 band A combis needed wheres Best price Anyone?

    Interest theory Simond... but the installer does not have to fix anything. You can fit and forget all You want. I think You are getting confused with someone like me who installs and repairs. unlike other installers that leave their customers swinging in the wind after they have took there...