Search results

  1. S

    Ripped Off 78 year old lady

    I'm in agreement here, if its only been a few weeks then it should of been free, i would also never charge for anythin without a detailed jobsheet, so you would know what i had done, but if he replaced ball valve and now its leaking he should of done it FOC unless it has nothing to do with what...
  2. S

    Freeze Master Spares

    Does anyone know where you can buy freeze master spares from i have a bare unit that i aquired a while ago, that needs regassing but i have nothing but the unit so need reducers, cream (told to use handcream?) and clamps but would prefer the new bungy clamps, an idea of cost would be good to
  3. S

    HELP Boiler working water heating BUT radiators not heating?

    try switching the 3port valve to manual see if the radiators warm up sounds like a 3 port problem
  4. S

    HInges

    Don't you have a trade counter @ screwfix whewre you are? could try toolstation £10 min delivery
  5. S

    Retraining to Boiler Engineer - any advice ?

    erm you mean geographically? lol
  6. S

    Powermax 155cp whistling noise

    Yes in 99% of cases it can be adjusted but they will need a calabrated diffrential manometer and a tee, sometimes they don't hold adjustment and then drift, so then you need a new gv. I wouldn't do one without a full service, and you could need baffles replaced which can contribute to the...
  7. S

    Feedback please

    owned by baxi potterton good budget/mid range boiler never had any problems with them, fitted a couple worked on a few more as with most boilers will work fine if installed correctly
  8. S

    Range Powermax 155x - Whistling Brass Thing on Top

    Kevin don't know about the burner gasket (could be)but when the gas/air mix is wrong on these they sound horrendous like a fog horn or an air raid warning.
  9. S

    Powermax 155 Blending Valve

    baxpoti - Now i am disappointed i thought i was going to learn something new :) no that went straight over my head, but now i get what you mean.
  10. S

    Powermax 155 Blending Valve

    Really, see my understanding has always been that the powermax including the 155 and 155x where designed by Range and where taken over by Potterton JUST as the powermax HE was about to be released or within its very early days, and that always seems to be the favourite excuss with them even if...
  11. S

    Powermax 155 Blending Valve

    Christian, Your deffinetly have the 155 not the 155x? when running your tap find the blending valve and feel all 3 ports on it, you should have one hot, one cold and one medium. like the 3 little bears. if you don't have the medium one after 30 secs spot on if not come back to us
  12. S

    luke warm water on a baxi combi 105e

    could be the dhw thermistor, if its showing its heating and its not, but only way to know is take a cold water temp, take a hw temp take away the diffrence compare the temp rise with the performace as lsited on product spec, also check flow rate
  13. S

    hot water

    problems probably a scaled / blocked hex needs flushing or replacing.
  14. S

    Do manufacturers make boilers with 4 seperate tappings?

    Gravity System you need to update to fully pumped can't replace a gravity boiler anymore.
  15. S

    Dripping Shower...Can anyone help?

    http://hydramax.co.uk/ Probably the CD if this one has a CD i don't know the model so don't know this, maybe scaled or just need replacing.
  16. S

    Current Climate Diversifying: Air Con

    Thats why now is a good time, it fits within the industry and is a growing industry even with energy prices as they are.
  17. S

    Current Climate Diversifying: Air Con

    Well in the currently climate I think it’s important as a business I diversify, I am looking at the possibility of air conditioning I have a handling of refrigerants cert for Heat pumps so can’t see much different have done brazing etc but someone told me this is becoming notifiable and would...
  18. S

    Multimeter faulty??

    Any idea how much it would cost, to get fluke to have a look Regards
  19. S

    Multimeter faulty??

    I can buy another one that don't bother me but all the readings are correct except VAC it doesn't make any sence. I wouldn't mind as well if it been knocking around in the van, but oh no, i was using this at the exact moment i had just done a VAC test and it was perfect 2 hour later comes back...
  20. S

    Multimeter faulty??

    Ok turns out i have spare battery in its case anyway, i have swapped these over and a brandnew set of leads from maplin and still only reading 28/30VAC when on 230/40 VAC