    I-ON16 with scantronic 734reur -01

    Not 100% but I think there is a front and back tamper switch on these door contacts. The front tamper is a spring and the back tamper a small button type. Both need to be closed.
  2. S

    I-ON16 with scantronic 734reur -01

    Z04 T(tamper) Living Room
  3. S

    Fence Post Repair/Replacement

    More than happy to pay just nobody seems to want the job. Very few fencing contractors around it seems.
  4. S

    Are these Pyronix PIR’s really this unsophisticated?

    What do you expect for a tenner! I’d fit a Pyronix TMD set up as tri-mode. No not at all. They are fantastic value.
  5. S

    R8 installed in 2014. Maintenance?

    I’d walk test the system every so often to check that the devices are working. Also set the system and trigger it. Disconnect the 230v supply and leave 10 minutes. If the battery holds then all seems ok. Replace the control panel battery on its 5 year birthday as this is recommended by most...
  6. S

    Are these Pyronix PIR’s really this unsophisticated?

    What do you expect for a tenner! I’d fit a Pyronix TMD set up as tri-mode.
  7. S

    Are these Pyronix PIR’s really this unsophisticated?

    What do you expect for a tenner! I’d fit a Pyronix TMD set up as tri-mode.
  8. S

    Fence Post Repair/Replacement

    Hi all I’m looking for advice on how to repair or replace the two broken fence posts as shown in the attached photo. I have previously replaced posts for standard 6x6 fencing but this fence is much larger and the posts much bigger. Ideally I would like a contractor to do the job but it seems...
  9. S

    Pyronixs enforcer - Siren wireless poll fail on a regular basis.

    If the new devices are dual frequency what are the two frequencies? 868 and ???
  10. S

    Pyronixs enforcer - Siren wireless poll fail on a regular basis.

    Very interesting. You have a document to back this theory up please?
  11. S

    CCTV Recommendations

    Why 30 days?
  12. S

    Keytags with new smart alarm upgrade

    Is always been that way but nowadays people are more aware of the situation due to social media etc.
  13. S

    Alarm (internal) went off when not set - tamper

    As I understand the siren requires 12v. The positive from the panel goes direct to the external siren + terminal. The negative from the panel goes through the normally closed tamper switch then to the siren - terminal. If the tamper switch is opened the siren loses its negative 0v and activates...
  14. S

    Alarm (internal) went off when not set - tamper

    Looks a poor connection on the tamper terminal
  15. S

    Pyronix enforcer hot spot

    Loads of stuff on YouTube
  16. S

    Pyronix Mini - Volume Options

    Speaker volume levels 1-7 1 = silent 2 = silent with confirmation double beep 3-7 = different audible levels. The confirmation double beep volume is programmed by the chime volume
  17. S

    pyronix central updates

    You got a link to the dongle mate pls?
  18. S

    Help with Accenta g4 roller door alarm contact install

    Blue & black to a spare zone. You may need to program the spare zone.
  19. S

    pyronix enforcer sounds

    Sounds like you are setting more than one area. Which letter are red when setting, A,B,C or D?