Search results

  1. T

    new shower installation

    its run at 35 amps, no way should you put a 40amp breaker on or use a rewirable, has to be MCB
  2. T

    new shower installation

    spark 123 41amps its rated at, and you put an 8.5 unit on a 32amp fuse... no need to recable mate, just swap the shower, no higher than an 8.5 though
  3. T

    fan fitting

    is this after you took the old light down?
  4. T

    Some Advice please chaps

    securespark who said anything about installing equipment?
  5. T

    Some Advice please chaps

    RMS, absolutely nothing, there was virtually no bonding at all.. Everything jam packed into a volex board with not a label in sight.
  6. T

    Some Advice please chaps

    fellas, In my opinion the house i am working on at the moment, the suppliers side of things is in bog order. 16mm tails from an ancient looking box, no modern cut out fuse in sight, virtually non existent bonding. The work i have just first fixed is completely independent of this consumer...
  7. T

    which fan?

    spark nothing at all in there yet. will be ensuite with a shower enclosure, and i have to drill the fans hole yet, what ya reckon?
  8. T

    which fan?

    fellas Ensuite do you reckon i am best putting in a low voltage or a mains extractor fan? very small ensuite, triple pole isolator outside room. Mains is preffered
  9. T

    What price you reckon fellas

    Ok, small empty bathroom, pipes need rerouting onto floor from wall, from tank cupboard next door. Reinstall electric shower, not a big job though as i took it off so fitting are all there. Install cast shower tray onto timber, same with wastepipes, route around the wall, picking up the...
  10. T

    NICEIC Domestic Installer Querie

    Fellas, This is a question mainly for niceic domestic installers. Just got my application forms back to send off the relevant paperwork ie; qualifications, public liability and my two address for the works examples. Now my query is? There is a separate piece of paper that details the...
  11. T

    Quoting For Garden Electrics

    I am never going to bother my arse again quoting for outside electrics. You spend 30minutes explaning the need for safety regarding outside power and when they get a reasonable quote from you, its the last you hear. These people actually think i can drill a hole in the wall and run some flex...
  12. T

    Pond Pump

    somebodys been on screwfix, lol
  13. T

    Pond Pump

    Fellas, Can anybody reccommend a cheap and cheerful pond pump. Told a customer the other day that i wont be fitting her £10 one she got from B&Q. So im looking for a cheapish one, any ideas?
  14. T

    Am I being thick??

    jiminblack yes you are right, if just the neutral is connected it around 5volts. Because you are round the 150v mark you do have the phase connected along the circuit. One of the causes of this is if one end of the phase is charred (burning out) the full 230v wont get through (neon testers...
  15. T

    What Timer?

    Fellas, Is this timer double pole and fused? If its not can somebody point me to one, im looking for a 3amp fcu to run soffit lights off?? http://www.screwfix.com/app/sfd/cat/pro.jsp?cId=A231864&ts=81665&id=59925
  16. T

    Total Re-wire for £1800.00 (2bed flat) is this needed?

    baldelectrician im a bit worried about your example including "chint" CEF sell these which i have used quite a lot of this year, i have had no probs with them, any reason for quoting them?
  17. T

    Black Museum

    heres another http://s49.photobucket.com/albums/f253/jacktomo/?action=view&current=Picture0013.jpg
  18. T

    How far to go with qualifications - a grey area it seems

    Barnie You can get full approval without the 2330
  19. T

    Insulation Resistance

    An effective test for insulation can only be made if the output voltage is maintained by the instrument
  20. T

    Water not hot enough

    Corgiman thanks for reply, can you elaborate a little??
Back
Top