  1. mickyg

    Combi boiler condensate pipe moved outside - is this wrong?

    Sounds like he has confused the prv pipe for the condense outlet :lol: Who rated him? His mates probably, just goes to show you can't trust those sites
  2. mickyg

    what is the best plastic pipe/fittings manufacturers?

    JG or Hep, not really much in it now that JG has the layflat pipe the difference in flexibility is minimal
  3. mickyg

    Vertical vs Horizontal radiators

    not necessarily, all radiators will have a quoted output so just go by that. I always oversize verticals by 10-20% as they don't generally heat very evenly. The more "designer" it is , the more useless they seem to be at actually heating the room
  4. mickyg

    Mains flush vs Powerflush

    if you have arcs of sludge in rads and hardened deposits inside pipework then you need a powerflush, as long as its done properly, good chemicals heated up past 60C will break down the sludge and make it easy to flush out. Mains flush is ok if the system is relatively clean but you want to...
  5. mickyg

    How to calculate head?

    i usually calculate head in minutes :P
  6. mickyg

    Powerflush?

    x800 has form for killing pumps. I would recommend a good mains flush rinse, which will only take around 1-2hrs, just to flush out all the existing water and refill and inhibitor.
  7. Untitled

    Untitled

  8. mickyg

    Flow rate vs boiler size

    I would not fit an unvented cylinder with 18l/min incoming. Bare min 20l/min and 2 bar dynamic. You could look at options of improving the main, but now your talking about stuff you really need a site survey for options.. honestly though how often will you really need to use 2 showers at...
  9. mickyg

    Flow rate vs boiler size

    i mean the flow rate of the showers. or at least desired flow rate
  10. mickyg

    Flow rate vs boiler size

    I usually recommend a boiler that will supply around 75% of the flow rate in hot water. so in your instance something supplying 14l/min or less. we cannot tell you how many kw required for your showers as you didnt supply the flow rate.
  11. mickyg

    Changing room thermostat for WiFi

    keep your knickers on, most of your questions would be answered on honeywells website or in the manual
  12. mickyg

    Changing room thermostat for WiFi

    bet your glad you replied to this one dan :lol: its long haul :P
  13. Untitled

    Untitled

  14. mickyg

    Are BG quotes getting more competitive ?

    glad i didnt quote for that one ! more time saved
  15. mickyg

    Sainsburys and British gas offer

    I wouldn't exactly call it competition :lol: I actually prefer it if customer has already had BG in.... how long warranty did they offer? what controls did they recommend? modulation? WC? No?? How much?? game over... :P :P :P
  16. mickyg

    Adelphi boiler?

    sure its not alpha?? never heard of adelphi and i have heard of most
  17. mickyg

    New cylinder

    should have an auto bypass not manual pump should be minimum 6m head on max 3 port valve would need to be 28mm with 28kw boiler but probably boiler is grossly oversized so downrate it to 15-18kw. as the cylinder has 28mm primaries it was probably specified for a gravity system and will have a...
  18. mickyg

    Are BG quotes getting more competitive ?

    blimey who let you out ! The voice of BG speaks again ! You have to be the worst advert for BG I've ever come across :lol:
  19. mickyg

    Are BG quotes getting more competitive ?

    I've been to 2 people to quote recently where BG have quoted, one was to replace a 12kw heat only boiler like for like in same location. BG quoted £3750, I told the customer that she should keep her Ultimate FF as it was a good boiler and it wasnt at risk just cos the electrical cover was a bit...