  1. mickyg

    Vaillant Ecotec Plus 937

    yes seperate pcb top right at the back. It was modified to help combat this fault and yes I used to work for vaillant.
  2. mickyg

    Vaillant Ecotec Plus 937

    get the store pump and store pcb changed.
  3. mickyg

    Calling all Remeha experts.

    It may not have been a big enough difference to trigger the fault 9. In any case boilers don't always act as they should according to the manual ! Poor circulation on most glowworm boilers gives a fault code which says NTC defective, replace ntc, check harness to ntc ! Im gonna stick with poor...
  4. mickyg

    Calling all Remeha experts.

    No not always, most boilers modulation profile is based on factors the software assumes about the system ie that there is a suitable flow rate through the heat exchanger and enough heat absorption to take away the heat. If the flow rate is too low the boiler can ramp up and hit a point of no...
  5. mickyg

    Boiler quotations - Exactly what to look for?

    why don't you contact sooey?? he's in your area i presume
  6. mickyg

    Calling all Remeha experts.

    not sure about remehas specifically but sounds like you have poor circulation
  7. mickyg

    Stuck in Keston hell....

    thats just daft though, outdated claptrap adding anything for hot water. High recovery cylinders and priority hot water is the way to go. Add 0kw for hot water. even if you did install the system in a traditional way, chances are that either a) there will be more than 4kw available to the...
  8. mickyg

    Stuck in Keston hell....

    as you know Kestons are rubbish, the new ones are no better. There are loads of boilers that use 80mm twin flue, if anyone you have had didn't know this then probably better to find someone who does, its not exactly a closely guarded secret. If you need the 55 kw output of the current...
  9. mickyg

    Boiler beyond economical repair

    most of the parts for these boilers are obsolette, servowarm went out of business years ago. If it needs parts its probably time to change it. Homeserve are a bunch of useless charlatans but I don't think they have done alot wrong in this case.
  10. mickyg

    Drain valve on Valliant ecoTec plus boiler

    Well coming from another ex vaillant/glowworm engineer i can only assume you need educating on repressurising expansion vessels. In 4yrs I replaced 3. Have you looked at the label on an expansion vessel to see the who made it? You may find the same vessels are fitted in numerous different makes...
  11. Untitled

    Untitled

  12. mickyg

    Why the leak?

    as dan said those things are sh1te. There's an oring in there that will prob be shot now. replace with a regular tail extension.
  13. mickyg

    Glow worm smart wiring centre fault

    well you are not gonna find the fault with a neon tester. You need a multimeter. also have you checked the valves not just stuck?
  14. mickyg

    Potterton Lynx Electronic - Engineer says may need replacing

    Funny how when its a repair your the only one who can do it, and now its a recommendation everyone agrees with you. must be amazing to be you Tony!
  15. mickyg

    glow worm flexicom

    no as long as you have isolated and drained the water its a doddle
  16. mickyg

    glow worm flexicom

    sounds like the plate heat exchanger is blocked or restricted, likely because the system is dirty.
  17. mickyg

    Potterton Lynx Electronic - Engineer says may need replacing

    its ancient, its failing, it was never a good boiler when it was new...skip it.
  18. mickyg

    Should I complain about this CH plumber? Is it safe?

    do we know what boiler it is yet? im gonna guess vokera compact if not
  19. mickyg

    Which boiler?

    if you have good flow and pressure than an unvented boiler might be a better option. would not have a 937 personally.
  20. mickyg

    Should I complain about this CH plumber? Is it safe?

    sorry mark, i cant agree, the soldering is amateur, the flue is worrying. There is absolutely no need for duct tape on a modern flue. Also you should be using flue clips which hold the flue tightly, not waste pipe clips. The flue will be wobbly within that clip, unacceptable. Phone Gas Safe...