  1. Spark123

    100W lamp and a 500mA fuse.

    About 40Ω for a 100w 230v lamp.
  2. Spark123

    1 50W Fluro sufficient?

    Assuming you mean 5ft 58w it ought to be sufficient for general use. That is without going too technical i.e. colour of walls, ceiling, height, particular usage and so on.
  3. Spark123

    What could be causing the vibration ?

    Maybe worth having your wheel ballances checked too, they can cause this issue.
  4. Spark123

    MOT Emissions (CO)

    It could just be the amount of crap in the exhaust system with it running rich. Probably just needed the Italian tune up.
  5. Spark123

    So i've installed a new outdoor socket!

    I'd still have some sort of double poled isolation for it indoors for the time when it goes wrong and starts tripping the RCD. 13A fused spur unit will suffice.
  6. Spark123

    So i've installed a new outdoor socket!

    Your contradicting information may come from older sources when it was notifiable, currently it isn't in England. Even though it isn't notifiable it still needs to comply with the building regs, i.e. it has to be safe. When you say it is a spur from a socket in 13A flex, that strikes me as not...
  7. Spark123

    Temperature sensor: NTC 25ºC=10K B3435 ±1% what cable?

    A few ohms of wire isn't going to make much difference to a 10K detector.
  8. Spark123

    70W HPS bulb on 230V mains with No Ballast - Just trips the MCB :(

    Same thing happens when you put some SON I lamps in fittings with external ignitors.
  9. Spark123

    infinite prime alarm tamper reset

    Have you made sure the tamper switch is closed on the door sensor you moved? There are default codes listed in the installation manual but these have probably been changed: https://www.tlc-direct.co.uk/Technical/DataSheets/ESP_Prime/prime_instalations_EL206186.pdf
  10. Spark123

    Shower extractor fan light not working

    It depends how it was installed. From what I remember the bezel around the outside of the vent turns and comes off revealing screws which attach to some arms that swing out. If you can get them to retract it ought to pull down and hopefully you should be able to detach it from the duct, push...
  11. Spark123

    Shower extractor fan light not working

    They aren't worth repairing, new ones are cheap. assuming a single 50w 12v halogen lamp this will do http://www.screwfix.com/p/halolite-electronic-transformer-loop-in-loop-out-large-terminal-20-60va/63579
  12. Spark123

    70W HPS bulb on 230V mains with No Ballast - Just trips the MCB :(

    Don't be surprised if the ignitor has welded it's contacts together.
  13. Spark123

    Electric Shower cable help!

    More likely there is a loose connection in the switch which is causing it to heat up. From that code it is probably 6mm with a 2.5mm earth but without seeing it myself that is only a guess. If the switch has gone toasty it will probably mean making off the cable again. My advice to is not to...
  14. Spark123

    Good old wylex...

    One that always puzzled me is the link between a transformer and a sub station, the setups I have seen are in what appears to be 4x single core armoured cables, probably in the region of 250mm^2 each.
  15. Spark123

    Can i add another twin line to my Sky Dish?

    The plastic bit pushes up to allow access to the two spare f-types. Once connected pull it back down.
  16. Spark123

    Upstairs light not working... (pictures attached)

    No, put the rose back as it was and put the two wires in the same terminal in the switch.
  17. Spark123

    Upstairs light not working... (pictures attached)

    I doubt it will be a faulty rose, the switch may be faulty.
  18. Spark123

    CCTV for Pensioners

    Like most things, if we follow the guidance we have a good chance of complying with the law. In this case the statutory instrument is the DPA (data protection act) which if you are using CCTV which films images of the street or anyone elses property you need to comply with.
  19. Spark123

    Is it worthwhile having an dedicated AV circuit ?

    Wouldn't it need bonding to the MET too as it is introducing an earth potential into the equipotential zone?
  20. Spark123

    CCTV for Pensioners

    Have a read of this first: https://www.gov.uk/government/publications/domestic-cctv-using-cctv-systems-on-your-property/domestic-cctv-using-cctv-systems-on-your-property