    Baxi 105e unstable heat on DHW

    Small issue with DHW on Baxi 105e combi. Recently hot water has been hot to like warm. Seems flame heat is dropping on and off. HEX was cleaned 18 months ago and after reading through many forum posts seemed seemed likely cause. New HEX fitted and diaphragm service kit as was letting by. After...
  2. F

    Annke kit direct connect to camera for image setup

    Scott, you are a star.. Annke does indeed have the virtual Host setting , All sorted now with full camera access through URL access via specific port . Thanks for the response.
  3. F

    Annke kit direct connect to camera for image setup

    Hi Sal, thanks for reply. I can still remotely connect to NVR on my internal home network using IE browser on PC. From here I can look at all settings views etc . I'm assuming that's what refer to , as the mobile app has nothing in it. When connected remotely I am sure I used to see a pass...
  4. F

    Annke kit direct connect to camera for image setup

    I have a Annke N48PAW POE Kit with four 5mp cameras. I recall when I first got it I could connect to the cameras via a URL shortcut within the NVR remote app. Now cant seem to see them anymore in camera mgmt. Ideally I would like to configure camera direct without climbing into loft and signing...
  5. F

    Baxi 105e random led's

    Update success, well nearly a year on with lights still jumping around, but diverter pin needed a little clean as was sticking. While cleaning thought i would replace heating and DHW thermistors. Pin cleaned, sensors changed and its like a new boiler. piping hot water at 50% on the dial and no...
  6. F

    New Patio advice

    Decided its was time to make a start on rear garden for summer barbies.. Had a partial patio before, mainly heavy duty square slabs laid on Concrete base. These have all been taken up now to leave whats shown in below images. My plan is to extend existing concrete bases to wider/larger area...
  7. F

    Baxi 105e random led's

    So little update,, New PCB arrived and installed to check functional. Installed reset, and fired up perfectly. However random led issue still there.. So seems not PCB related unless I have two with exactly the same issue. So Thought I would check Thermistors, (All readings were taken by removal...
  8. F

    Baxi 105e random led's

    Thanks Ian , have to admit this will be my 2nd PCB. Installed refurb pcb about 8 years ago, but your comments are welcome as no doubt I would have been standing there like a lemon waiting for things to happen. Hopefully this one being brand new will last as long or longer than last . :D
  9. F

    Baxi 105e random led's

    Cheers all, Being someone who likes to be prepared , managed to source a new genuine PCB at a very reasonable price.. So at least will have it in my back pocket, should things take a turn..
  10. F

    Baxi 105e random led's

    Another question, although led's are playing up, i wouldnt have noticed unless i had flipped the panel down to check pressure. So boiler operates as it should, am i being naive if i just ignore it until some actual symptoms appear. ??
  11. F

    Baxi 105e random led's

    No flickering when cold , only power light . Hot water demand takes about 30-45 seconds to hit 70 but led,s jump up and down gettingb there. Led's still jump after he demand stopped, is hw demand is off and all led sitting at 80 degrees. Changed to CH and ramped up thermostat, took couple of...
  12. F

    Baxi 105e random led's

    Hi all , general question , happened to notice led's on baxi 105e randomly flashing up and down and do not seem related to any error codes. PCB was replaced with newer model about 5 years ago, Boiler is probably knocking on 12-14 years old so bit long in tooth. Runs fine, heats and gives hot...
  13. F

    Honeywell AG8 sounder

    Not sure what happened then ,. Nothing has changed , all I did was take cover off , clean and activate anti tamper a few times and cover back on ,, now arm/disarm still works fine ,. Trigger sets off bell and internal Sounder and disarm stops both imediately .. ie no over run on bell. Maybe anti...
  14. F

    Honeywell AG8 sounder

    ??, what isn't ??
  15. F

    Honeywell AG8 sounder

    Strangely i triggered bell with cover of by releasing anti tamper.. after disarm panel did show bell tamper trigger.
  16. F

    Honeywell AG8 sounder

    Well little update.. Thanks to all for comments, decided to test bell from control panel,, forced bell test and the disabled,, bell continued to sound. Ear defenders ready unscrewed cover from bell, and pushed screw anti tamper fully back ,, bell stopped. seems anti tamper was the culprit...
  17. F

    Honeywell AG8 sounder

    hmm ok thanks,, will do some digging , have a spare bell box ,, tad extreme but may wire that in and test ..
  18. F

    Honeywell AG8 sounder

    Alarm has worked and tested flawless for 5 years, No wiring changes been made in that period of time,, just strange the bell now continues for 5 mins after a trigger and disarm.. Even been stable during recent power cuts..
  19. F

    Honeywell AG8 sounder

    Slight issue, Installed Honeywell Accenta G4 in 2013 with Honeywell AG8 sounder. Having carried out walk teats on numerous occasions alarm seemed to work well including the occasional accidental setting off. Daughter forgot to disarm last week when walking downstairs. she entered code and alarm...
  20. F

    1000 kitchen unit on dot n dab

    Need to fix 1000 kitchen wall unit to dot n dab wall. Problem I have is the void behind plasterboard is 45mm. Was planning to cut plasterboard and batten wall for stronger fixing . any other suggestions on a suitable fixing . ( to add one side of unit will be in block work )