  1. A

    Hot Water tank ballcock querie!

    Surely its a full brass ball crane with a solid rubber diaphragm, it sounds like you have a WC float valve in your CWST. Al
  2. A

    Toilet overflow problem..

    The diaphragm inside the float valve has failed, look for a name on the valve, or take a picture and post here. Al
  3. A

    Boosted water system

    Im sure Grundfos is a good starting point.
  4. A

    seized stop cock

    Personally, If you can shut off the supply in the street, then replace the stopcock for a nice new working one. You could try backing off the packing gland, see if it free's up the spindle. Al
  5. A

    Mixer Taps

    I would compare both flowrates, if neccessary restrict the higher with a valve. I think the kitchen sink tap you plan might not look great, would it be possible to fit wall mounted controls with spout coming from the wall ?. Al
  6. A

    correct method of installing a strap on boss?

    I use solvent weld right round the strap, some dont go right round with a screw to hold together.
  7. A

    Flush pipe

    I had one the other day, Was a VIRQUIN model.
  8. A

    Baxi Solo PF Conventional boiler

    Can I replace coil only ?. Or the whole gas valve needs replacing ?. Al
  9. A

    Baxi Solo PF Conventional boiler

    tried tapping around with a hammer, no luck. Al
  10. A

    Baxi Solo PF Conventional boiler

    1.5k ohms @ the solenoid. open circuit measuring across l/n with wires disconnected. cheers Al
  11. A

    Baxi Solo PF Conventional boiler

    I'm getting 0 mbar for dynamic working pressure. I'm getting approx 21 mbar at pilot. I'm getting 230 to pilot soilenoid, then 230 to burner solenoid. I think the gas valve is fooked, unless blockage is likely ?. Any comments guys. ? Al
  12. A

    Baxi Solo PF Conventional boiler

    I beleive im qualified to test my own burner pressure, working pressure. I reckon the unit is 10 years old, I might get him to fit new gas valve, seems to be around £85 inc. many thanks plummerman Al
  13. A

    Baxi Solo PF Conventional boiler

    No problem, I'm assuming power is ok, as the power lights work on the boiler, please correct me if im wrong. The fan spins up no bother, and the boiler will stay lit for maybe 30 mins, just no heat from flow. I'll get my gas safe pal to have a look, he's more of a combi installer then a...
  14. A

    Baxi Solo PF Conventional boiler

    Flame area is only the pilot area, burner not fully lit. Al
  15. A

    Baxi Solo PF Conventional boiler

    Recent problem with this boiler. Selecting HW/Heating, boiler files up fine, took me an hour to realise the water or heating wasnt working. Looking at the flame picture, the burner seems to produce a very small flame around the pilot area, only in the corner of the burner area. The...
  16. A

    I quit

    All the best matey
  17. A

    toilet waste pipe

    your local plumbing merchant would be able to supply the fittings matey. Al
  18. A

    ABS Slip coupling?...

    And I used the sandpaper flap wheel only the other day for buffing down a power pod, It never crossed my mind for the 4". Great tip Dextrous! Al
  19. A

    ABS Slip coupling?...

    I use Muggles way to file the inside hip. Pain in the ass when its 4" soil. Al
  20. A

    wash hand basins in shools

    Expect 3 pipe supply, keep "active dead legs" short as possible. Will you be chlorinating or someone else ?. Al