    Im employed with a national construction company, however for the last 6 weeks ive been sitting in the house being paid basic hours. Everybody knows construction is struggling with the recession. When will it recover ?, tomorrow ive got a meeting to discuss my contract, which is bound to...
  2. A

    What does a Diverter Valve do ?

    Its a valve that is triggered to activate HW or Heat. I guess you have HW and no heating or other way round. There is a good chance it will fail at one point
  3. A

    No central heating

    I would let BG know thats its still not working. It sounds like the most common problem with combi's, the divertor. read the FAQ http://www.diynot.com/forums/viewtopic.php?t=37170 Al
  4. A

    electric shower plumbing

    If you look in the manufacturers instructions it will tell you what is suitable, generally 15mm copper/plastic is used. Al
  5. A

    Issues with microbore

    You say you had experience with copper pipes, so you should be fine. You might want to increase from your microbore to 15mm, with a couple of yorkshire reducers/straights. Then you can get two standard 15mm valves for the new towel rail. I would mount the towel rail, then fit valves and...
  6. A

    mains frozen!!

    The wifes hairdryer is nearly burnt out...
  7. A

    Dripping Kitchen Mixer Tap?

    I guess the ceramic discs are scratched, try fitting a strainer before the taps to collect grit. strip down the taps and try a little grease on the faces of the discs, remember it will be drinking water so look for a potable grease/lub. Al
  8. A

    Single Cold Radiator

    More than likely the pipes have frozen, if you can access the pipes, then a hairdryer works well. Opening the door to allow warm air from inside will help.
  9. A

    Plumbing an Electric Shower

    Ideally you dont want any pipe showing, there should be a knock out plastic piece. Looks like a 15mm compresion elbow would suit, using 15mm Hep20 would be a easy job. Al
  10. A

    Open vented HW problems

    To be honest, the flowrate at kitchwn HW is very poor, Ive tried blowing mains up to the cylinder with only a slight improvement that lasts a few days only. I agree with the draw off, nothing is level, potential for airlock must be huge. where so I start to rectify, maybe replace draw...
  11. A

    Open vented HW problems

    Ok then, hopefully reducing pump speed will still heat the house in this cold weather. Al any other suggestions
  12. A

    Open vented HW problems

    those are older photos when i replaced the M/V 2 winters back. The pump is on speed 3, has always been. Im now thinking Ive been brushing my teeth, and 2 yr old son with INHIBITOR. When you ask for pics of F&E is it pipework at cylinder or pics of the actual FE tank.? NEW PICS...
  13. Untitled

    Untitled

  14. Untitled

    Untitled

  15. Untitled

    Untitled

  16. Untitled

    Untitled

  17. Untitled

    Untitled

  18. A

    Open vented HW problems

    The boiler is downstairs in kitchen DoItAll if thats what you mean ?. Thanks for the help so far, especially Kevplumb lol. I'll try upload more pics of HW draw off etc. If the coil was gone, shouldnt my F&E overflow ?. Cheers Al
  19. A

    Open vented HW problems

    ok http://www.diynot.com/network/Al-Glasgow/albums/ dont know if pic will load for you. Al