    New electric hob - should it smoke? Or have I broken it?

    This is quite normal and should dissappear quite quickly. When the parts are made they will have oil residue etc on them which will burn off during first use. The manual usually states this.
  2. L

    undercabinet lighting Hardwired

    What size fuse or MCB is protecting the 1mm cable?.
  3. L

    Garden wiring - I'm confused.....

    How have you earthed the steel armour?
  4. L

    Yet another Pull Switch wiring question!

    Damn, must type faster!
  5. L

    Yet another Pull Switch wiring question!

    Black isn't a neutral, it will be switched live. Red to C, put a piece of brown sleeve or tape over the black and connect to L1. Earth to earth as you said.
  6. L

    Installing an outside light - cable route?

    Before you get too carried away, with the power turned off unscrew the switch from the wall and see what cables there are at the switch. If there is no nuetral you will need to take a feed from the nearest ceiling rose.
  7. L

    Bathroom Electrics

    As it is a bathroom everything you mention will require 30mA RCD protection.
  8. L

    Floodlight

    I think you will find that building regs now state 100 watt maximum for floodlights.
  9. L

    consumer box question ... HELP!!

    I hope you didn't pay him then if the job isn't completed yet.
  10. L

    consumer box question ... HELP!!

    B-A-S. You'll be telling me next the "professional" who installed the shower wasn't actually an electrician!
  11. L

    consumer box question ... HELP!!

    You can't just change the mcb without first identifying what size cable you have, how it has been installed and measured the EFLI of the circuit. Get your professional back to put in the correct size mcb as stated in the MI and retest your circuit for you. If you change the mcb yourself then you...
  12. L

    Ikea Wall Light no Earth

    Do the manufacturers instructions say it needs an earth connection? Is there a picture on it of a square inside a square?
  13. L

    How much would a spark charge to change a CU

    PIR before board change, board change and then final testing and certification in 3 hours???. I must be doing something wrong. Please get your electrician to let us in on his secret!
  14. L

    New Downlights, No Earth Fixing

    Either connect 2 core cable to your existing choc block then to the new fitting or remove your choc block, connect the neutral and line to your new fitting then put the earth from the T&E to a single choc block (don't forget the earth sleeve).
  15. L

    Fitting new light in garage - will I need a certificate?

    Famous last words!! Make sure you make a note of where all the wires are in the current fitting before disconnecting it.
  16. L

    Fitting new light in garage - will I need a certificate?

    Is the garage attached or detached from the house?
  17. L

    17th edition and Tri rated cable

    By the time you have messed about with the trunking you may aswell use T&E. No registered spark can sign your work off for you.
  18. L

    Identifying shared neutrals

    A question to all you domestic electricians. When carrying out a pre works survey for a consumer unit change, apart from going in the loft and tracing cables is there a simple check for shared neutrals on the lighting circuits prior to quoting?. Fortunately I haven't been caught out yet but I...
  19. L

    ch wiring

    From your diagram the socket which has the burner and pump plugged into only becomes live when the heating is on via output from terminal 6. When the hw is on the only thing getter a supply is your other pump at the bottom of the picture via terminal 5. Where is your 2/3 way valve and how is...
  20. L

    45A Cooker

    45A rated cooker, where did you get that information from?