  1. GasMan1965

    Needing help in replacing ye olde boiler - where do I start?

    It depends if your going for a combi or a separate boiler and hot tank !!
  2. GasMan1965

    Needing help in replacing ye olde boiler - where do I start?

    Why dont you call 3 local guys and compare quotes ?
  3. GasMan1965

    diagnose my over pressure in heatline combi

    Pressure vessel will most likely be the answer.. you will see a valve on the vessel like a tyre valve. If you push the pin in like your letting a tyre down then if you get water come out then its split inside,, if you dont get water then it needs pumping back up to the requited pressure which...
  4. GasMan1965

    Removing shower inlet plug.

    The same way you removed the plug, pull the collar back towards the fitting and away from the pipe and pull pipe..
  5. GasMan1965

    Needing help in replacing ye olde boiler - where do I start?

    What area are ya ?? Im not sure how the forum feels about it but Im sure someone will be along soon to say if its ok !!
  6. GasMan1965

    F&E tank for a megaflo?

    Yeah not a good idea mate unless ya gonna change the boiler and another weak spot will be the rad valves !!
  7. GasMan1965

    Water cistern hot and cold split

    Ok the bigger side of the black tank is the cold supply for the cylinder and the small side is the heating feed.. I hate these bloomin things so always advise they change em for a nice combi :wink:
  8. GasMan1965

    Needing help in replacing ye olde boiler - where do I start?

    I would advise a Worcester Bosch or a Vaillant as they are very good,, also the Viessman .. You can supply yourself but be aware the Fitter wont get involved with problems as he aint supplying !!
  9. GasMan1965

    Mono taps help please

    Ahhh the truth comes out :lol: :lol: In that case just change the taps for the right type and put the others on fleabay :wink:
  10. GasMan1965

    F&E tank for a megaflo?

    If the old boiler cannot be a sealed system then yes youll need to keep the F&E tank
  11. GasMan1965

    Mono taps help please

    There are mains pressure taps and gravity tank pressure taps .. Basically the mains 1ns will be restricted in some way to deal with the pressure ..
  12. GasMan1965

    Removing shower inlet plug.

    You dont have to but you may notice a flow diff if you use another !!
  13. GasMan1965

    Mono taps help please

    Not really mate,, youll have to change the taps I think,, contact the supplier and ask them if they can be converted :wink:
  14. GasMan1965

    Mono taps help please

    Wrong type of pressure taps ? Kinked flexi connectors? Air lock? Are the others OK ?
  15. GasMan1965

    Large hex/allen keys - can't find any

    How about 1 of those tapered rad valve keys .. Or as Chris suggested Halfrauds :lol:
  16. GasMan1965

    Glowworm Xtrafast 120 Overheating

    F5 Overheat fault.. Overheat stat operated Maximum temperature exceeded Check thermistor connections Air in system with thermistor at maximum setting Faulty overheat stat connection
  17. GasMan1965

    What heating system to have?

    Not far from the airport here .. Just below the Downs eh , nice area :wink:
  18. GasMan1965

    which system boiler to go with new megaflo?

    How many bathrooms you got ??
  19. GasMan1965

    Hot water not working.

    Kingfisher is a floor standing Conventional Boiler with a cylinder in airing cupboard.. Are you fully pumped and fully controlled ,, ie Y plan or S plan ?