    BAXI BERMUDA PROBLEM

    :lol: aww kevplumb we was just bumping our gums no need to banish us to the CC :(
  2. ismellgas

    BAXI BERMUDA PROBLEM

    hmm.. ok i'll check the tap because i didnt check it when i was there, probably should have but this wasent the main reason i was at this house was a kind of " i'll have a look see" You've earned yourself a thanks
  3. ismellgas

    BAXI BERMUDA PROBLEM

    ok guys baxi bermuda fire and back boiler fault here thats confusing me a bit.. well just the fire thats the problem. radiant fire is lighting but only the two outside radiants are coming on fully. can anyone think of a reason for this? a new burner has been fitted by another plumber but...
  4. ismellgas

    Waste pipe size

    its supposed be a max of 2.5/3metre run before uping the pipe size so i would go with the 2'' (50mm). it would be better for blockages etc, people put allsorts down the kitchen sink!
  5. ismellgas

    no hot water, help !!!

    F*ck primatic cylinders.. str8 to hell! lol :lol: hate em'. try cracking the nut at the top of the cylinder like said in a post above, i would think any air in the cylinder would go up the vent though:?, still worth a try i would empty it all and refill because theres a chance the "air...
  6. ismellgas

    ideal isar he30

    Yeah the expansion vessel can be taken out and a new one fitted in the boiler but the boiler needs to come off the wall for this. I've had to do this before found it a pain in the a*se but very "do-able" the plumber just does'nt want the hassel of taking the boiler off incase he disturbs...
  7. ismellgas

    Glasgow Plumbers quick question

    Hello glasgow plumbers did any of you go to cardonald college and if so did you do E1,E4&5 combi boiler fault finding? im goin on this course soon to try step away from site work into a more maintenance-esk role and was just wondering if anyone had any info on it? or could recommend any boiler...
  8. ismellgas

    Worcester 28i RSF *very* slow to provide hot water

    it could be the spindle on the diverter valve is very slow in making with the micro switch. i would check this. also if the fan is noisey then give it a clean incase its just fluff etc, if its the bearings then lubricate them. or tighten the screws holding the fan assembly incase its just...
  9. ismellgas

    Hot Water Hassle....Really Appreciate Some Help!

    The alternating hot and cold at the hot water outlet suggests a sludge or scale build up in the domestic hot water heat exchanger. either have it replaced or try flushing it. hope you get this sorted pal its a joke how many times plumbers have been out
  10. ismellgas

    Underfloor Heating Question

    I've never fitted underfloor heating before mate but i cant see it doing any damage. Is there any kind of problem which is making you want to change the pump speed?
  11. ismellgas

    cap off clay soil pipe

    I tend to use a bit of slate and break it so it rests in the collar then pile in the cement.
  12. ismellgas

    Downstairs toilet smells

    hmm.. if theres no obvious signs on leaking on the stack then its probably just the sh*tey old pan connector. if your toilet is going back in the same i would suggest using a bent pan connector (same one thats in) better than trying to get a tight 90' on a straight flexi. you can also get a bent...
  13. ismellgas

    central heating working but hot water not!!!!!!!

    I think you might be talking about the air pressure switch (thing with hoses from it) I think its probably a diverter valve problem although it could be the flow switch. here is a link to someone changing the diaphragm in a diverter valve on a 24cdi theres pictures at the side so you can see...
  14. ismellgas

    Disconnect back boiler but leave fire?

    Thank you all for the input. :D
  15. ismellgas

    Vailliant VCW 242 EH not firing up?

    sounds to me like diverter valve diaphram as said earlier.. saying that though, you should check the flow switch.
  16. ismellgas

    piping question for raising radiator

    need to drain the heating mate. There should be a drain valve terminating outside at low level. If its a combi boiler make sure the filling loop is off (it will be) and open the drain (with the boiler off) and watch pressure gauge go to zero. if it is a system boiler with cylinder the heating...
  17. ismellgas

    electric shower. Head constantly drips. Gainsborough 400

    sounds like its passing right enough.. is it an electric shower or mixer? try the gainsborough website for spare parts or to at least find out what part you need, also do they not have a customer support line to advise you on how to go about repair?
  18. ismellgas

    Inserting Junction into an existing soil stack

    use a 4" Flex seal. its pretty much a rubber collar that you simply slide up the pipe then line up the fitting then slide it down over the cut and tighten with jubilee clips. magic!
  19. ismellgas

    Disconnect back boiler but leave fire?

    thanks for the info guys. gas_man_gaz i'm not sure what you mean by drilling the heat exchanger :?