Search results

  1. Z

    Toilet cistern wont stop leaking?

    Are you sure it isn't just condensation off the cistern?
  2. Z

    Wylex 2nd consumer unit

    It's 4mm2 SWA
  3. Z

    Wylex 2nd consumer unit

    Hi I have this consumer unit connected via a Henley block to the meter. It powers my garage via the 32A MCB and the shower via the 40A MCB. It only has a 63 A RCD. I know I can apply diversity. So I'd this safe? Also, is the RCD actually a RCCB or should there also be an overcurrent device...
  4. Z

    Any Smart Meter Installers in the House?

    I wish you good luck. My parents have a similar issue with British Gas due a Gas Meter going haywire. To fix it they replaced bith gas & electricity meters. That was a year ago & since then the meters have been dumb. They are both nearly 80. BG have been useless. Promised multiple visits & not...
  5. Z

    Am I allowed to change the hob placement and extend the wiring myself?

    For your safety chuck the "mains tester screwdriver" in the bin. They are not fit for purpose. Always use a two probe tester.
  6. Z

    Dimplex storage heater not working.

    1) The "electrician" should have done continuity tests to see what had failed 2) If the above failed to give conclusive results then I would have temporarily fitted a plug to it so I could have powered it up to see where the power was/wasn't getting to. 3) Storage heaters are very basic & there...
  7. Z

    Erics Rubbish

    Stick it on E-bay! You would be surprised what you can sell. People want to repair things instead of buying new. I sell a lot on E-bay & it is surprising how much you can get for spare parts, someimes more than a working item! I recently sold the working bit from my parents broken dishwahser for...
  8. Z

    Help identifying toilet washer

    I think I've found it now. Viva Skylo!
  9. Z

    Help identifying toilet washer

    Hi, Realised last night that my toilet was slowly overfilling. I had assumed that it was a fluid master as the washer looked similar but it isn't. Any ideas on make and where to get a washer from? Fluid master washer on the left. My washer on the right. I've put the old one back in for now as...
  10. Z

    Voltage drop

    I suspect capacitive coupling is going on here. Can you measure the live relative to earth as well as neutral....
  11. Z

    Gas Safety Certificate - No Flue Clips

    Don't forget the £139 quoted by your letting agent probably includes their "arrangement fee" They have their own trades people on their books who get the work & then charge this on top. It's all corrupt! Anyway, get the work done, £139 is cheaper than a court case when you injure your tenants!
  12. Z

    Cost effective solder fume extractor?

    What I meant to actually type was CPC do one for under £20 https://cpc.farnell.com/duratool/d03288/fume-absorberfan/dp/SD02209 or buy the carbon filters & attach to a fan! Must clean my keyboard!
  13. Z

    Cost effective solder fume extractor?

    CPC do one for under £20 https://cpc.farnell.com/duratool/d03288/fume-absorberfan/dp/SD02209 or but the cabon filters & attach to a fan
  14. Z

    Samsonia 28A Perfect Model J vice

    I've actually got it working! Needed to tighten the spring a bit more. Not w=easy when a Jubilee clip is holding it together. Anyway, it's working a treat. Thanks for your help. If anyway has a spare spring.....!
  15. Z

    Samsonia 28A Perfect Model J vice

    I think it is working as it should given the screw thread
  16. Z

    Samsonia 28A Perfect Model J vice

    Hi All, I have inherited the above vice a while ago & given the curent situation thought it was about time I did something with it. I have a couple of questions:- 1. Any ideas where I can get a replacement spring from?The original has snapped but I have bodged it for the moment with a jubilee...
  17. Z

    Multimeter sparked

    Are you sure you are not applying pressure to a terminal or wire that is then shorting out on the case or another earthed item? Your multimeter may be OK, the wiring inside the thing may be the issue!
  18. Z

    Ideal Isar HE24 Pressure Gauge Replacement

    Hi KenGMac, it's on the water side, the combustion cover will not be removed! Thanks for your concernt though
  19. Z

    Ideal Isar HE24 Pressure Gauge Replacement

    Hi All, Pressure gauge has gone on my boiler. Which side of the isolator is the pressure gauge? i.e. If I shut off the heating valves under the boiler do I draing the heating or the boiler. I suspect the boiler but just want to check! Thanks!
  20. Z

    Yale replacement mechanism

    Hi, Thanks for the replies. Comparing front (working) to back door (not working) the latch bit doesn't go in as far when the door is open unless you pull really hard on the handle. Took the mechanism out at the weekend & measured up the central gearbox bit. I have ordered a replacement part...
Back