    Unswitched FCU to dimmer switch

    sorry have also got 230v at dimmer. lights in garder are screw in mushroom shapped with silver reflective bit on bottom(if this makes sense!)
  2. N

    Unswitched FCU to dimmer switch

    yes lights worked . have bypassed dimmer and still no lights. Havent checked at lights in garden
  3. N

    Unswitched FCU to dimmer switch

    Hi. Having a problem with a unswitched FCU to dimmer switch which turns on outside lights. Problem is they wont work. It is wired as follows. Ring main live and netural to "in" on back of FCU. Neutral out from fcu connected to directly to wiring feeding outside lights. Live from fcu to dimmer...
  4. N

    Boilermate II no central heating but hot water.

    Thanks all it was Central heating pump after all. Changed and now working fine.
  5. N

    Draining hot water cylinder???

    well just open hot then! picky
  6. N

    Draining hot water cylinder???

    No. You will need to drain the cold water storage in the loft. Just turn of the mains water or tie up ball valve. Open hot and cold taps to drain quicker. Once water drained and stopped coming out of taps go for it. ( Hot water cylinder will remain full except at the very top). Once...
  7. N

    Pumped shower running mainly on cold.

    Yes all sorted. It was the cartridge. Changed it over for a new one and works fine now.
  8. N

    Boilermate II no central heating but hot water.

    yes bled radiators. Thermostat set to above 30 degrees to get it hot. Set boilermate to max on winter as well. Pretty sure not boiler thermocouple as evrything appears to be fine there.
  9. N

    Boilermate II no central heating but hot water.

    The top pump is working. I thought this was the return to the boiler from the boilermate - have i got this the wrong way around? Even if i have i thought it would still get the rads a bit warm? Bottom pump is the supsect one. Tried running on all three speeds and bleeding . Any ideas how to...
  10. N

    Boilermate II no central heating but hot water.

    Drained down boilermate to work on rads and as thought boilermate would not refill. Tried to backfill through rad ( already of the wall so valve easily accessable) and rads now full of water. Problem now is no hot water in rads. Couple of questions : 1.Taps have very hot water so...
  11. N

    Boilermate II - how does it work?

    As thought boilermate would not fill. Tried to backfill through rad ( already of the wall so valve easily accessable) Problem now is no hot water in rads. Couple of questions : 1.Taps have very hot water so assume that boilermate is full of hot water even though it doesnt feel warm. Is...
  12. N

    Plaster blown

    OK Thanks for advice
  13. N

    Plaster blown

    Wall are breeze block. I take it i can use one coat on that? As for aqua board is it really essential in wet areas if whole bathroom is tiled, grouted and sealed. Seems like additional money for nothing as already waterproof.
  14. N

    Plaster blown

    Wont tiles stick to undercoat plaster then-if not why not? Thought about dot & Dab but small enough as it is!
  15. N

    Plaster blown

    The plaster on my bathroom walls is completely shot and going back to blockwork. Walls will be tiled so only needs to be good enough for that. Was thinking of just undercoat plaster on blockwork. Any suggestions?
  16. N

    Pumped shower running mainly on cold.

    Cheers mate. will give it a whirl.
  17. N

    Pumped shower running mainly on cold.

    Wll do. Thanks for your help much appreciated. ONE MORE question. I assume i cant take the non return valve out just incase of problems with backflow (forget water regs for a moment)
  18. N

    Pumped shower running mainly on cold.

    Ok. Without sounding thick as i normally fit and forget these things where is the non return valve on the shower valve- by cold inlet?
  19. N

    Pumped shower running mainly on cold.

    My guess was a faulty cartridge. Please you confirmed that this most obvious. Most thermostatics have a button you can press to go above 40ish degrees. this one does not which i thought was odd and would probably have solved the problem!