  1. M

    Have I been rinsed by unnecessary power flushing???

    Firstly before we condem the engineer for doing an unnecessary job did the flush remove a lot of dirt? The boiler may well be repairable but its quite old would you have a car this long? I cant comment on price as prices differ with geographical location, as for difficulty its a considerable...
  2. M

    3 years of air in sealed system and now a leak

    Hi first question are you sure it was air and not Hydrogen in your rads ? did you try lighting it as it left the bleed nipple? second question in the realm of anythings possible its possible that they caused a leak. third question your boiler has an auto bypass installed internally so shouldn't...
  3. M

    Radiators RED HOT !!!!!

    Do you mean hot to touch or hot when they should be off ? The temperature of the radiators is set by the boiler thermostat not the room thermostat it may just be set to high or possibly faulty,what system do you have and what is the make and model of the boiler,Paul
  4. M

    Heatline Solaris combi noise

    Hi X100 isnt a cleaner you should try X400, a power flush would be better but more expensive it depends on your budget really hope this helps Paul.
  5. M

    Vizo 24 internal fuses keep blowing

    Hi its probably the divertor valve leaking into the actuator and causing an overload,I dont want to be the bearer of bad news but the boards are often damaged when this happens so it could be an expensive fix im afraid. Paul
  6. M

    ariston eurocombi 92

    Hi if you run the hw with the heating off does the boiler do anything? it sounds like the diaphram in the divertor valve may have failed
  7. M

    A Curious Boiler Problem

    Hi its possible that the hole that allows water to act upon the pressure sensor is blocked and is only allowing water through slowly taking a long time for the sensor to reach the min pressure thus allowing your boiler to operate. when you next drain your system you should remove it and ckeck...
  8. M

    New boiler install - Potterton pump too powerful?

    Hi the pump you have isnt a great deal more powerfull than the one you had it can pump to a height of 6 metres as oppossed to 5 with your old pump have you had a conversion to a combi system from open vented? its possible that your flow and return have been reversed this isnt always a problem...
  9. M

    heatline whistling noise

    Hi my first thought would be to call your installer to check combustion ect then call heatline for a warranty visit if its due to a fault on the boiler.
  10. M

    Ravenheat csi 85

    If you remove the pcb cover (after switching off the power) look to the left hand side of the pcb you should see the stat wires the connector says room stat, disconnect them and put in a link wire if your heating works when you turn the boiler on then you need to check your external controls...
  11. M

    Ravenheat csi 85

    Hi it sounds more like a controls issue to me if the ignition board was faulty your HW wouldnt work, if you press the DV microwswitch with no water running all the heat goes into the heating circuit which is why it appears to work. I would try linking out the external controls first and the...
  12. M

    Radiator not filling after refitting during decorating.

    your boiler is a sealed system boiler and requires topping up manually,this is done via a filling link normally under the left hand side of the boiler using a white plastic key.(it could also be fitted onto the pipework below the boiler) the overheating could be due to the boiler firing dry...
  13. M

    Routing of gas supply pipes

    Hi its not permitted to run gas pipes within a cavity( with the exception of some living flame fires) so i imagine the pipes chased into the wall as you first thought hope this helps Paul.
  14. M

    Should there be an extractor or window in this room?

    The boiler you have is a room sealed fan assisted boiler and (provided that the clearances set by the manufacturers are met ) requires no additional ventillation. Theres no harm fitting an extractor if you want one provided its not to close to the flue outlet, hope this helps Paul.
  15. M

    Baxi Inset2 Gas Fire

    My first thought would be when was it last serviced ? Its probly due another now.
  16. M

    Please let me know how to install shower pump under boiler

    Hi im sorry to tell you but that looks like an Elson tank you have there and you cant fit a shower pump to that type of tank at least none that I know of hope this helps Paul.
  17. M

    Glow Worm 30cxi hydroblock or not ?

    Hi it could be leaking from the dhw side which would have do effect on the system pressue and from the amount of water you have lost i think thats the case here. It can be a difficult job especially if access around the boiler is restricted, however at 6 years old its worth repairing I would...
  18. M

    help with boiler cutting out

    Hi Steve it sounds like your expansion vessel has either lost its charge or has failed,if you feel confident enough you can let the pressure out of the system and open the shrieder valve on the vessel(if you have access to it) and see if water comes out.If not you can pump it up with a bicycle...
  19. M

    Baxi Combi 105 HE

    My Guess would be a small tear in the H/W diaphram the large one at the front on left hand side. Its easy to replace and involves no gas work,you can get them from parts centre or Ebay hope this helps Paul.
  20. M

    Remove Gas Fireplace

    No its not i'm afraid, the fire is an integral part of the boiler and its flue and cannot be seperated you should leave it alone for your own safety.