  1. M

    C24 Ideal Boiler

    Also the Ideal mini 24 has no pilot light.
  2. M

    Trying to move a radiator, but....

    Hi you have a one pipe system in your house it shouldnt be difficult to swap the radiator to the oppersite side just google one pipe central heating you will find loads of imformation and diagrammes hope this helps Paul.
  3. M

    Poor Water Heat From Ravenheat Boiler

    Hi while it is possible that the valve has simply failed its also possible that dirt in the system is a factor, it might be an idea to add a cleaning chemical then flush out and add an inhibitor to prevent the problem re occuring.
  4. M

    Central heating system blowing fuses

    Firstly the fuse should be 3 amp secondly is the fuse ok on hot water only and blowing on heating, this would suggest the pump is pulling to many amps and causing the problem this would be what I would check first.
  5. M

    New gas supply needed to a boiler?

    Without seeing the installation it is difficult to give an answer,given the size of your new boiler it is quite likely that your existing pipe work was undersized. It is possible that upgrading only half the pipe work is sufficient as its more about the resistance to flow than how much gas a...
  6. M

    radiators for loft conversion

    I Mean that the return for the cylinder should be closest to the boiler and any radiators need to be connected after that point oth,erwise water can circulate back through the return and heat the rads when H/W is on hope this helps.
  7. M

    Ravenheat RSF820/20T Not Firing Up

    The fact that the pilot light is lit suggests the thermocouple is working correctly, that being the case it would seem your fault lies elsewhere and could reappear. When was it last serviced? It may be wise to have a service carried out by an engineer who is familiar with this boiler before you...
  8. M

    radiators for loft conversion

    Sounds like its a regular boiler to me if so then no you can't do that the radiators would heat whenever the boiler fired,you should tee in the flow after the c/h valve and the return should be teed after the return for the h/w cylinder. also if open vented it is important that the F&E tank for...
  9. M

    Help Me Please

    It looks like one half of an integral filling loop from a combi poss ferroli optimax.
  10. M

    Baxi 105e Water under Furnace

    Yes its more than likley the O ring seals in the H.E that req replacing.
  11. M

    Baxi Combi Boiler 80e Printer Circuit Board PCB has blown?!

    What he means is although the Pcb is obviously burnt and therfore U/S its possible that the fault lies elsewhere in the boiler. I have seen a few with burnt out fan relays due to low resistance in the fan windings causing to high a currant to flow,as suggested have your rgi check the resistances...
  12. M

    Hot water issues

    Just a thought but how is your system controlled ? Are you using the built in timer and the VR 61 module as this is default set to give HW priority and must be changed in the menu to allow CH and HW to run together hope this helps.
  13. M

    Vaillant 438 boiler - hot water only not working

    mikeyg is correct that boiler using that built in timer is designed to work using the vr 65, you need to get your installer back dont bother ringing Vaillant you will be on hold for ages to be told the same thing.
  14. M

    Vaillant 438 boiler - hot water only not working

    Are you using the vr 65 control centre with this boiler set up ? it wont work properly without it. I know the default setting is for priority hot water and you can change this using the menu described in the back of the manual for the vr 65 I have not seen hot water only when heating is on hope...
  15. M

    Ravenheat csi85T - CH comes on when set to HW only

    I had this same problem turned out that the divertor leaked slighty from the pin and shorted the micro switch out causing the boiler to fire up, as the divertor was in ch mode it heated the rads. There is no pre heat on the hw on this boiler so I would check the micro switch first.
  16. M

    Air Pressure Switch?

    There was a problem with the honeywell air pressure switch fitted to this model boiler this has been replaced on later models by the hoover air pressure switch. Is the switch on your boiler metal or white plastic ? if it is metal then it is the honeywell type and I would advise you to have an...
  17. M

    Ravenheat CSI85T

    Sutton St Helens
  18. M

    Ravenheat CSI85T

    I am familiar with this model and am near St Helens If boiler not sorted give me a call I have worked for warm front and was for a time sent out to inspect systems for upgrade/boiler exchange and given that your boiler is only 18 months old it would be unlikley to be replaced if repair costs are...
  19. M

    pilot light going out

    I sounds like the fan is not slow running when boiler is idling does your pilot light go out overnight? remove the cover and inspect the fan it should run slowly with no demand for heat if not check for power at fan if power is present replace fan