    When ballasts go bad....

    Not clever to have the EM's on a different cct. but at least they have quality white ware, Armitage Shanks!!
  2. Qedelec

    Help on installing oven and hob

    No it would not 9.8KW divided by 230V = 42 Amps
  3. Qedelec

    seperate circuits

    I would expect this departure to identified so no-one working on the installation is left in any doubt that power to that room is on two separate boards. maybe marking the sockets from one board as DB1 and the others as DB2 would surfice, but I am no lover of labels, they drop off.
  4. Qedelec

    16mm earth

    I hope this is sweated on, and not a clamp!
  5. Qedelec

    earthing

    The purpose of the green/yellow sleeving is for identification purposes, do you think it should be identified? Regulations require all cables to be adequately identified.
  6. Qedelec

    trunking

    Under part P of the building regulations, work in a kitchen is notifiable to Local Area Building Control @ your council. if you plan to carry out the work yourself and you are not able to 'self certify' then you will need to inform LABC before you start work.
  7. Qedelec

    Bonding a power shower

    The reason for bonding the lighting to the shower circuit is to lower the cpc resistance (circuits in parrallel) but I have never been convinced the reduction in trip time would be significant.
  8. Qedelec

    moving a socket

    You could add another socket as a spur if this socket is on the ring. Otherwise you will need to extend the cable either by adding 2 junction boxes or crimping a new cable onto the old. Use ratchet crimpers if using the second method.
  9. Qedelec

    Danger

    Sadly we do not have the same powers as Gas fitters to protect the public from themselves.
  10. Qedelec

    new consumer unit advice

    Are you aware Runci that if you disconnect the old board and have not checked insulation resistances, that the new board with RCD protection might keep tripping. You are then not legally allowed to reconnect the old board. This is why we test before disconnecting. Well some of us do!!!
  11. Qedelec

    Extractor hood

    There is always super glue or Araldite
  12. Qedelec

    New Cooker advice pl

    Manufacturers will fit a 13Amp plug if their appliance is under 3Kw.
  13. Qedelec

    New Cooker advice pl

    If its fitted with a 13Amp plug then you are ok plugging into a square pin outlet.
  14. Qedelec

    Proximity of Electric socket

    I understand your concern but there is as much chance of a burst pipe as of the house falling down so there should be nothing to concern you.
  15. Qedelec

    Proximity of Electric socket

    None other than common sense. You should consider sighting an outlet in a safer place or blanking it off. Regulations with regard to sinks require 300mm clearance from the lip of the sink. So what do you think!
  16. Qedelec

    Lighting upstairs in a pub can't find the board.

    Ahh! so that's where I've been going wrong.................
  17. Qedelec

    What's a "qualified" electrician ...

    I just checked and a firm I subbed for is not listed although he is Dom Inst. I thought he was a cowboy and he still owes me for the last invoice, yeeha!!
  18. Qedelec

    Anyone seen one of these before

    No but I bet there's rubber wiring attatched. Came across some lead sheathed cable made by Pirelli in a listed building recently. The building dated to William III (1697) Those timbers were hard as iron to drill through.
  19. Qedelec

    What's a "qualified" electrician ...

    Wow I'm there too. Usefull link I must save it.
  20. Qedelec

    Manual for a Canon Fax-B100

    Thanks Igo. Late delay due to the pc refusing to show acrobat files, a reboot sorted that. Looks pretty similar and the funtions I have checked so far, tally. Thanks again. Isn't it amazing what people throw away!!!