    Connecting Texacom Alarm Box

    it could also be -s for siren! or -r for ring check the outputs from your panel also, what panel is this oddy siren going onto? Oasis
  2. O

    Concept alarm light control keypad question..

    with rehgards to your GJD light controller (not the ADE Concept intruder alarm system) press the AREA buttons on the GJD keypad, and conduct a walk test. please report back to let me know what happens Oasis
  3. O

    British Gas / Dyno Alarms or Pyronix, Visonic or Alexor ?

    get three quots from local firms that are either SSAIB or NSI registered try to move away from the national companies especially those that there main income is gas supply and drain cleaning!!!! Oasis
  4. O

    Code change for Concept System alarm

    easy one; press the PROG button then enter 0123 TAMPER light should show change battery put cover back on press RESET all done Oasis
  5. O

    Honeywell Galaxy G3-48 Gone Haywire Help Please

    OP have you managed to sort it, if not contact me and i will talk you through what to do. Oasis
  6. O

    Scantronic 9651 adding new users

    scantronic (cooper) one thing NEVER to do is prefix ANY code with a 0 ! Oasis
  7. O

    cheap wireless fire alarm

    is the `cheap stuff` approved? i doubt it very much. sorry there is no such thing as `cheap good wireless fire alarm kit` we, as a firm will only us the approved wireless kit in our fire alarm installs (thats if we do them, but that is few and far between) is it really a good idea to...
  8. O

    Scantronic 9751 entry time problem

    simple really you must have one device, usually the first one, set as FINAL so it will detect the correct entry intot he property and start the count down timer, all other devices within the system should be set as intruder or entry circuits, (as you need them, because i cant see what you...
  9. O

    Veritas R8 - No of alarm activations in programming mode

    the number of alarm activations before the system locks out and wont set the bells and whistles off until you reset it. in other words; if you set it to two activations it will go off twice and so on but after the last activation , it wont re arm and go off again! Oasis
  10. O

    honeywell accurra panel problem

    aux fuse blown? wired them up wrong? not connected the power to them? it could be one of the above or yoiu have not programmed them in? check all connections, wiring, programming and fuses!!!! (and do it with a meter, not just looking at them!!) Oasis
  11. O

    Alarm power cabling

    Ah, so you already have a spur (switched) then just change it to an un switched. i should really read and re read you original post Sorry!!! Oasis
  12. O

    Fire alarm charges by Freehold owner

    to the OP; access must be able to be obtained for any person who requires access to the fire detection and control equipment. in case of false alarms and or testing of system we have a number of systems out there that are one main panel in a looked area, with multiple users and...
  13. O

    Fire alarm charges by Freehold owner

    Owain the system use (i expect) is a BS5839 system not a domestic detector set up!! because it has to RESET by a person!!!! so a `hush buttom` would not be of ANY USE !! Oasis
  14. O

    Alarm power cabling

    electrical regs come into this now, not alarm regs!! ALSO: be aware that your mains board has got mains in it, SWITCH OFF BEFORE MAKING OR BREAKING AND CONNECTIONS WITHIN and the usual one is; As you are `adding ` circuit` it needs to be done by a PART P contractor (i know its a pain...
  15. O

    securitech active 5 alarm system

    boy a M & W autodialler, the last time i removed one of them was last year in an old Post Office Tellecomunications hub!!!! yep an old one!!! it was connected to a M & W CPS 4 (i think it was a CPS 4 it was the one were the engineer reset was a button on the PCB) you should update to a...
  16. O

    Can anyone recommend a good alarm company?

    the best way a9we have always advised) is to chat to your neighbours! also you could check out the ssaib website and the NSI website just dont go for the big boys as they will charge you far to much!!!!! even if the say its only £99.00 to install and then tie tou to a minimum 3 year...
  17. O

    house alarm service ?

    8 in a day, so you start at about 5 in the morning and finish about 9 at night then!! some of our systems can take over 4 hours to do!!! but some take about an hour!! we have a set of buildings that cover 3 acres all with security and fire detection within and these take about 2 days...
  18. O

    house alarm service ?

    it does depend on the size of the site to be honest, we have not charged £45.00 for years (and i mean over 15 years ago) even on a simple audible only we charge £65.oo plus vat for a routine inspection and test! maintenance charges for a years cover start from £95.00 to over £500.00...
  19. O

    house alarm service ?

    hey Joe 90 you can come and do a few service caals for me at that price!!!!! if you do this for a job there is no way you can make a living charging that!! Oasis
  20. O

    internal speaker

    Ian i agree with you as well, but as you and i (and others here) some people just do not have the ability to be able to chnage the system out, (well thats why they are here!). we would generallychange the system out for a newer panel (usually a Galaxy, as its our prefered panel). yes the...