  1. O

    Wireless external sounders ......

    sheesh!!!!! silly or what!!! Oasis
  2. O

    Wireless external sounders ......

    we dont use wireless EWD`s but i should expect that they would signal a tamper? well i would hope they would, but you never know do you, until you look into it a bit deeper. Why ? Oasis
  3. O

    Fire Alarms

    to satisfy your building control officer you ONLY need to fit what i have told you above! if you want to go the whole hog see and do what Alarm has said! £10 to £15 quid for a smoke head ???? sorry i dont think so!!! appolo S65 optical £34.56 base for a bove £4.23 plus vat basic...
  4. O

    Intermittent clicking from Smoke Detector

    the clicking noises are the relay in the head, it does not come with a sounder. Oasis
  5. O

    Intermittent clicking from Smoke Detector

    very very old A2Z ionisation (12volt) smoke detectors, linked to a control panel, (intruder alarm panel, not a fire panel). we used to use these years ago, were pretty good, cleaning them will NOT help as they are ionisation (americurum 241 0000.1% a radioactive substrate) and they are not...
  6. O

    Fire Alarms

    sounds like a standard domestic (3 floor) smoke detector install. so you will have probably been asked for one detector to each landing and a heat detector in the kitchen. if you fit that (or better get your sparks to fit them, as they will need to be signed off) that should satisfy...
  7. O

    Honeywell Accenta G4 - What is the "Test Outputs"

    tonyW2 it Alarm Receiving Centre (ARC) not alarm receiving company or any other connortation!!! used to be known as a central monitoring station or company, but EN got there hands on our regs and changed everything!! Oasis
  8. O

    Honeywell Accenta G4 - What is the "Test Outputs"

    the test outputs is used to test the programed outputs to trigger communication devices to the ARC, simple really!!! Oasis
  9. O

    Fire alarm pricing

    handyman, the price was given to you `off spec`we didn't send an engineer to view the job. so it was costed using our standard pricing methods. you can say what you want in relation to the costs for equipment, but as you are not an approved fire/security company you really cant odds on what...
  10. O

    Fire alarm pricing

    is it really worth putting wireless in for that amount of devices? FCU = Fused Connection Unit maintained LED emergency lighting / positions?? is the building a grade 1 or 2 ? (that would be the only reason i can think of for wireless) base panel would be about £1500.00 to 2k...
  11. O

    Galaxy 2 wireless PIR mating

    as we fit the Galaxy Wireless all the time, there seems to be nothing wrong with your PIR also, if the system was set up correctly your panel would know when the battery is going low, as it would tell you on the keypad. you cannot use any other type of PIR on your system it has to be a...
  12. O

    Help in ID of controller System and instructions for alarm

    well then lets get my crystal ball out and see what you have fitted............ sorry, nework busy, you will ahve to give some more info! or even photos Oasis
  13. O

    ADT unable to remote reset, have to do it in person??

    sorry but thats what happens with Aunt Daisy. you and alot of other people are in the same boat to be honest. there is an add on that can be connected to your panel, but unless you ask for it, they wont fit it! its called a remote reset module. we used to fit them all over the place...
  14. O

    ts690 alarm will not set after power cut

    my personal advice would be to contact a local alarm company near you to come out and re program it for you, they might advise that you up grade the control panel, but you don't have to if you cannot afford to / want to, but it will be easier for you to get a pro in to sort it out as you...
  15. O

    Is what I have done to my electric shower safe?

    sorry to say this but.............. the gene pool is a bit low so i really think that if you carry on doing this sort of thing you will be joining it very soon!!! safety devices fitted to appiances are there for a purpose DO NOT REMOVE AND OR MODIFY ANY OF THE INTERNALS UNLESS YOU KNOW...
  16. O

    How do I reinstate house alarm?

    you will need to run a new cable from the control panel, not the keypad to the front (final) door and fit a door contact. battery wise a 3.2 amp hour will do it external bell (siren) unit battery, well if it is old and tired, just change the box for new shiny one, or get a new battery from...
  17. O

    Fire Alarms

    More info needed. exactly what have they asked for; BS5839 pt 1 to 4 2002 or BS5839 part 6 2002 it makes a BIG difference, if you need some personal advice PM or call me. we are a fire and security company, and advice is always free!!! Oasis
  18. O

    Honeywell Galaxy 2 Alarm Problem.

    02 have ceased there text via comms service (i think it will all be done about march 2012) so you will have to change the sevice you use, or fit a speech dialler
  19. O

    Wireless expander question

    Visonic then, thats sooooooo easy to do Oasis
  20. O

    Customers, if you...

    as a pro installer i do not expect a tip, (other than, `the best way to get that cable up is via this route sort of tip !!! NOT!!!) all i want is the invoice paid at the end of the job!!!!! but copious amounts of tea are always nice!!! choccy bikies please and please make it with SUGAR and...