Search results

  1. Gasinayr

    Vokera Mynute 25he

    Had the same problem today with a Vokera Unica 32 he ( code 34 ) phoned tech help, advised fan gubbed, new fan required
  2. Gasinayr

    Vokera Mynute 25he

    check fan speeds as described on page 23 of Mi for boiler
  3. Gasinayr

    vokera option, no central heating

    check the pump, it doesn't run on hot water mode only c/h
  4. Gasinayr

    Vokera Boiler/Central Heating

    Any luck with your boiler ?
  5. Gasinayr

    Vokera Boiler/Central Heating

    It's a job for a GRI or plumber. The valve sticks in the hot water mode for two reasons, Dirt in the two chrome pipes from the water diaphragm housing at the left on the boiler and the valve itself stuck. To check get your plumber to remove the water housing and see if the pin operating the...
  6. Gasinayr

    Vokera Boiler/Central Heating

    As DP said the boiler would not ignite with the pump was faulty. Looks like the divertor valve is sticking in the hot water position. There is a service kit to repair this. I think its part no 0858 and costs around £10.00
  7. Gasinayr

    ariston microgenus 23 mffi dhw valvle location

    Follow the cold water inlet pipe and you will find it located between the gas valve and pump
  8. Gasinayr

    Overheating Vokera Linea 735

    Renew the changeover valve bobbin and washers common fault with lineas
  9. Gasinayr

    Danfoss TRV stuck pin

    Go to Heat Spares in Helen Street Goven for your silicon grease or as Kev posted any plumbers merchants
  10. Gasinayr

    Danfoss TRV stuck pin

    The head is removed by loosening the allen key grub screw and pulling head away from body. You can remove the brass bush that houses the stuck pin without draining down the system. Slacken it off a small amount of water will come out then seal remove pin clean and grease with silicon grease and...
  11. Gasinayr

    Linea 24 CH not working

    Yes based in Ayr. Yes I do repairs and servicing to Vokera boilers
  12. Gasinayr

    Linea 24 CH not working

    Selector switch broken, very common with older vokera lineas
  13. Gasinayr

    Potterton Promax HE Plus

    Just to let you know DP. it was me that placed the post about magnets affecting the pcbs and you are way off the mark about me being silly and clueless. I have 25 years with scottish gas 16 years self employed also service agent for Vokera ( before they dumped us all ) service agent for Valor (...
  14. Gasinayr

    Potterton Promax HE Plus

    I had the same problem and it was due to fridge magnets on the front casing. removed them and boiler worked fine
  15. Gasinayr

    Hot water has stopped flowing from combi!

    have you used the valve at right hand side below boiler to top up the water pressure. If so have you returned it to the upright position. This is a three way valve. up water flow, horizontal off, down wards fill system.
  16. Gasinayr

    Three port or Two port valve ?

    I think you plumbers are referring to the wiring for the new boilers. Some boilers controls are 24v therefore two port valves would be required. if boiler is 240v controls then the three port will be ok
  17. Gasinayr

    Frankie Miller

    Saw Frankie live in the Pavilion in Ayr in the last seventies. The man was brilliant. Got through two bottles during the main show and a third for his encore which lasted 30 mins. Pure class.
  18. Gasinayr

    Vokera Linea 735 leaking water from motorized Valve

    3 port valve kit. part no 01005127 front cover part no 2904
  19. Gasinayr

    Digital DHW Tank Thermostat ?

    Try Potterton PTT2 cylinder stat
  20. Gasinayr

    Netaheat mercury vapour switch.

    Try Roger Smith of J R Smith and son. Calbuslea Road Ayr. They were potterton agents for years and stopped trading last year. They have shelves and shelves of spares for Potterton. Tried selling them to me when they shut. you might be lucky. I'll try to contact Roger and get back to you
Back
Top