    Radiators hot at top,warm at bottom, Flow rate??

    Sorry to hear you have been having such issues which should have been put right by the plumbers you employed. The pipe work network could be the issue which is something that cannot be really commented upon from here as it has to be viewed in place. If the previous plumbers have correctly...
  2. F

    Cleaning a Heating System

    It all depends on a lot of information you have not provided. Make and model of boiler as some have aluminium components Radiators like wise what are they made of ? Hot water cylinder for example a Primatic unit has to be treated differently to an indirect unit. Pete
  3. F

    Is this a decent price for a Complete Bathroom Refurb

    Looking at the pics in more detail I would say it was a very good price. Do not forget it also covers any call backs over the next 12 months. Pete
  4. F

    Is this a decent price for a Complete Bathroom Refurb

    Value is in the eye of the payer :D Pete
  5. F

    Is this a decent price for a Complete Bathroom Refurb

    Without viewing the job in person very hard to guesstimate. But the price you state for the work listed is not expensive. Pete
  6. F

    Mega Flow / Santon immersion heater elements.

    Your elements could be acting like a sacrificial anode. Pete
  7. F

    1/2" male to female flexible connector

    Just be careful and do not overtighten as the compression coupling has a sharp edge to accomodate the olive which will cut into the rubber seal and then leak. Pete
  8. F

    Help to Identify Shower On/Off Valve

    If all else fails you could always butcher a 3/4 "bath ceramic valve as it is usually a bit of grit that has scored the face of the shut off plate. Pete
  9. F

    No water after turning the mains back on

    Has the faulty stop cock been replaced or is it still in place possibly shut. How did the water co test the meter, was it over the phone? Pete
  10. F

    Unvented system losing pressure again...

    Tape a plastic bag on your prv warning valve and see if any water leaks out. Yes they can let by at any pressure of the spring is weak. Pete
  11. F

    Unvented system losing pressure again...

    I think you are getting confused with the boiler sealed system pressure and the hot water pressure in your cylinder as they are 2 seperate things. What expansion vessell was changed, the boiler or the cylinder? If you mean the pressure guage on the boiler is dropping to zero then this has...
  12. F

    Another loft conversion question..toilet.

    Paul a Saniflo is never a good option. Do as you say and extend the existing vent pipe to service the wc in the loft, generally the AAV,s are 4". Pete
  13. F

    Pipe bender marking/ denting pipe

    Possibly your guides are wearing out. Check the bolt/nut holding the arms together are tight and not allowing any rocking movement. Hillmore are a good make so I doubt one of the arms has been bent which happens to cheap units. Pete
  14. F

    faulty under floor heating

    Make model and poss a pic of the unit. What is the pressure and temp of the circuit. Is there flow through the loops? Pete
  15. F

    boiler does not fire when timer comes on - unless HW also on

    Have you bought a Multi meter yet, they are only £10.00 a lot cheaper than changing motorised valves. Is the room stat sending a signal to your wiring centre? Pete
  16. F

    Chip and Pin Devices

    I wish I got cash payments, I even get cheques for £20.00 :roll: which is a right pain having to pay in. Pete
  17. F

    Devices on boiler return pipe

    You are correct one is a drain cock and the other is a manual air vent which you simply open to release the air and tighten by hand to close. Pete
  18. F

    Water cylinder and F+E tank positioning/DIY Heatbank

    The Feed and expansion tank relates to the heating circuit not your hot water cylinder. I think you are getting confused. Pete ps what is a PHE?
  19. F

    Back to wall toilet

    They are really awkward to connect to a floor soil pipe. The only way we get around it is to use an elbow multikwick connector which has an extendable section. Attach it to the pan outlet first and then insert the other end with the pan away from the wall then push the pan back to the wall. Pete
  20. F

    New boiler installed - didn't check pipes

    What regulations as to thickness of pipe were they refering to as this is new to me? Pete