  1. C

    heating engineer required in warrington

    if you go to gas safe webiste and search for a engineer it will tell you your local engineers, and phone numbers etc.
  2. C

    Central heating flowing into expansion tank

    Try magnet on the pipework if it sticks it's blocked or full of sludge :)
  3. C

    Shower pump won't stop

    Sounds like a stuck switch or faulty switch inside the pump
  4. C

    Which Central Heating System Should I Choose?

    Don't you mean a unvented system as you have removed the tanks from the loft it would have to be unvented
  5. C

    Lounge Thermistat Universal

    When your boiler was fitted ( If fitted properly) a room thermostat should of fitted this is part of " boiler interlock" and is a minimum requirement . I would first advise you to see if the installer would come back and correct it if not a wireless stat can be very easy to fit if you Know...
  6. C

    Water coming out of condensate pipe

    Unless it has been raining and running down the flue
  7. C

    Can I get a COMBI with a 15mm gas connection?

    Your not on a gravity system it's fully Pumped isn't it ?
  8. C

    Ideal Standard Mexico 470 ff

    Contact a gas safe registed engineer ( you can find them at the gas safe website by typing in your postcode) and let th have a look at it as you shouldn't be touching a boiler if you are not competent in it, and going by the question you are not competent. Trying to repair your own boiler...
  9. C

    Would installers have problems if I supply my own combi?

    Dunno about the installing but If I was you I would put the Cdi in not the junior the Cdi is a better boiler and gives better hot water flow
  10. C

    Replacing Condense Trap on GlowWorm 30 CXI

    Blocked drain / condense pipe?
  11. C

    Kingfisher MF RSL80

    This should be in the combustion chamber section if you are gas safe registered if not get a gas safe engineer to it.
  12. C

    Replacing baxi solo 2 40rs with Worcester boiler

    Nothing wrong with the ri get a Worcester approved installer and you could get up To 7 years warrenty ( go on Worcester website).
  13. C

    Should we install TRVs? Do they save energy?

    Room stat is a must that will help trv can save money if used correctly ( keeping room doors shut)
  14. C

    Tap Still Dripping After changing both Valves

    That style tap will drip a little when you turn it off and it still has water in the spout. This is very normal for it to drip after a few seconds of it being turned off, does it stop after about 10 seconds ?
  15. C

    Glow worm Swiftflow air leak seal

    Turn the boiler off at The mains and call a gas safe engineer to have a look as it sounds like your boiler is unsafe and needs to be looked at
  16. C

    Baxi combo 80e, no power to the boiler fan with DHW

    Go to gas safe website and look up a local engineer who will be able to fix the fault for you
  17. C

    Extending balanced flue outlet

    Call an oil engineer
  18. C

    Thermostat issues

    Yeah the white/ grey ones but if the top one is giving power to the bottom one something isn't right it sounds like both are working but wiring fault do you have 2 programmers ? To set times or one for hot water an 2 for heating