  1. twgas

    Central heating not working

    Do you have the means for safe electrical testing?
  2. twgas

    glow worm 15 hxi boiler

    Check the wire going to room stat, should be mains voltage.
  3. twgas

    glow worm 15 hxi boiler

    Yuore not getting power from the room stat, its either faulty or there is a problem with the actual wiring
  4. twgas

    glow worm 15 hxi boiler

    When you call for CH do you get 240v(ish) on the white wire to the valve?
  5. twgas

    glow worm 15 hxi boiler

    Does the valve move to mid position if both heating and water are called for?
  6. twgas

    Gas Meter - this looks dangerous, who's responsible?

    I find, very often, the meters are originally fitted correctly then the cupboard, shelf, bracket or whatever is supporting/holding it is altered making the installation less than perfect. If the house changes occupants the new people blame the installer.
  7. twgas

    Vibrating when heating and boiler on

    More details, system type, boiler......
  8. twgas

    upstairs radiators wont heat up

    Seized anti-gravity valve?
  9. twgas

    Ariston micro genus 27 miffi external stat

    I find it odd that to start with you fitted a stat and it didnt work, then, after a few comments, a service has stopped it working !
  10. twgas

    baxi 105e boiler fault

    Could be air in the boiler, turn heating on, boiler will lock out so reset a few times. It might need a new diaphragm.
  11. twgas

    Altech Thermostats

    The down arrow should reduce the set temperature, pressing the"BL/FROST" button for 3 seconds should set 'stat to frost protection mode (5deg) Try here http://assets.grahamplumbersmerchant.co.uk/product-docs/13332/13332.pdf for instructions
  12. twgas

    Spec of pipe to gas fire

    Does your installer not know?
  13. twgas

    Cold rads

    Have these 2 rads ever worked? What boiler/system do you have? How many rads, in total do you have? What have you done to try and rectify the problem?
  14. twgas

    (Hopefully) Redoing CH with PEX, need advice

    I would NEVER recommend either plastic pipe or microbore, most manufacturers stipulate a minimum of 1metre of copper pipe from boiler. 22mm main circuit and 15 to each rad. Having flow and return slightly diferent lengths won't be a problem
  15. twgas

    Baxi 105 Fault on Fan or Flue

    Sounds like you need someone who knows what they're doing, call in a pro.
  16. twgas

    Help with central heating project

    I would go for a wireless programmable room stat, the cost is more dependent on make than functionality. The wiring would be, quite possibly, like for like, or at least minimal alteration
  17. twgas

    Pipes to radiator bent?

    You could try removing one of the nonworking rads and rigging a draining system to the valves and run water through it, do both valves individually and leave it running for a while. If you just open the valve, water discharges, turn it off, it might give you a false impression of being ok.
  18. twgas

    Megaflo Unvented Water Heater leaking through tundish

    Sounds as though you may need a new pressure reducing valve, personally i usually replace the complete control group.
  19. twgas

    New Home: radiators not heating up

    Have you checked the system pressure? It should be 1bar minimum
  20. twgas

    Pipes to radiator bent?

    I would suspect a blockage in the plastic pipe. The first place i'd look would be the pipiework on the landing as it sounds as though the 4 rads may be fed from there.